PURPOSE: The pivot-shift phenomenon has been identified to be one of the essential signs of functional anterior cruciate ligament (ACL) insufficiency. However, the pivot-shift test remains a surgeon-subjective examination, lacking a general recognized quantitative measurement. The goal of the present study was to validate the use of an inertial sensor for quantifying the pivot-shift test, using a commercial navigation system. METHODS: An expert surgeon intra-operatively performed the pivot-shift test on 15 consecutive patients before ACL reconstruction. A single accelerometer and a commercial navigation system simultaneously acquired limb kinematics. An additional optical tracker mounted on the accelerometer allowed following sensor movements. Anteroposterior (a-p) tibial acceleration obtained with the navigation system was compared with three-dimensional (3D) acceleration acquired by the accelerometer. The effect of skin artifacts and test-retest positioning were estimated. Repeatability of the acceleration parameter and waveform was analyzed. Correlation between the two measurements was also assessed. RESULTS: Average root mean square (RMS) error in test-retest positioning reported a good value of 5.5 ± 2.9 mm. Mean RMS displacement due to soft tissue artifacts was 4.9 ± 2.6 mm. The analysis of acceleration range repetitions reported a good intra-tester repeatability (Cronbach's alpha = 0.86). Inter-patients similarity analysis showed a mean acceleration waveform correlation of 0.88 ± 0.14. The acceleration ranges demonstrated a good positive correlation between the two measurements (rs = 0.72, P < 0.05). CONCLUSION: This study showed good reliability of the new device and good correlation with the navigation system results. Therefore, the accelerometer is a valid method to assess dynamic joint laxity. LEVEL OF EVIDENCE: II.

Quantitative assessment of pivot-shift using inertial sensors.

BONANZINGA, TOMMASO;MARCHEGGIANI MUCCIOLI, GIULIO MARIA;ZAFFAGNINI, STEFANO
2012

Abstract

PURPOSE: The pivot-shift phenomenon has been identified to be one of the essential signs of functional anterior cruciate ligament (ACL) insufficiency. However, the pivot-shift test remains a surgeon-subjective examination, lacking a general recognized quantitative measurement. The goal of the present study was to validate the use of an inertial sensor for quantifying the pivot-shift test, using a commercial navigation system. METHODS: An expert surgeon intra-operatively performed the pivot-shift test on 15 consecutive patients before ACL reconstruction. A single accelerometer and a commercial navigation system simultaneously acquired limb kinematics. An additional optical tracker mounted on the accelerometer allowed following sensor movements. Anteroposterior (a-p) tibial acceleration obtained with the navigation system was compared with three-dimensional (3D) acceleration acquired by the accelerometer. The effect of skin artifacts and test-retest positioning were estimated. Repeatability of the acceleration parameter and waveform was analyzed. Correlation between the two measurements was also assessed. RESULTS: Average root mean square (RMS) error in test-retest positioning reported a good value of 5.5 ± 2.9 mm. Mean RMS displacement due to soft tissue artifacts was 4.9 ± 2.6 mm. The analysis of acceleration range repetitions reported a good intra-tester repeatability (Cronbach's alpha = 0.86). Inter-patients similarity analysis showed a mean acceleration waveform correlation of 0.88 ± 0.14. The acceleration ranges demonstrated a good positive correlation between the two measurements (rs = 0.72, P < 0.05). CONCLUSION: This study showed good reliability of the new device and good correlation with the navigation system results. Therefore, the accelerometer is a valid method to assess dynamic joint laxity. LEVEL OF EVIDENCE: II.
2012
Lopomo N; Signorelli C; Bonanzinga T; Marcheggiani Muccioli GM; Visani A; Zaffagnini S
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/126880
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 88
  • ???jsp.display-item.citation.isi??? 73
social impact