At the Department of Physics of the University of Bologna a new intensified linear array detector is under development. The core of the system is a digital intensified CCD camera, the electron bombarded charge coupled device (EBCCD). The main innovation is a coherent rectangular-to-linear fiber optics adapter coupling the 1 in. diameter photocathode of the camera with a linear 129 mm × 1.45 mm strip of Gd2O2S:Tb. In this way a high spatial resolution over an extended length is obtained. The detector works as an X-ray scanner by means of a high-precision translation mechanical device to inspect a 13 cm × 18 cm area. A complete characterisation of the system has been made in terms of linearity, dynamic range, modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE). At last, radiographic tests on a set of samples have been made and will be presented.

BETTUZZI M., CORNACCHIA S., ROSSI M., PALTRINIERI E., MORIGI M.P., BRANCACCIO R., et al. (2004). A NEW LINEAR ARRAY DETECTOR FOR HIGH RESOLUTION AND LOW DOSE DIGITAL RADIOGRAPHY. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 213, 227-230 [10.1016/S0168-583X(03)01577-5].

A NEW LINEAR ARRAY DETECTOR FOR HIGH RESOLUTION AND LOW DOSE DIGITAL RADIOGRAPHY

BETTUZZI, MATTEO;CORNACCHIA, SAMANTHA ROSARIA;MORIGI, MARIA PIA;BRANCACCIO, ROSA;CASALI, FRANCO
2004

Abstract

At the Department of Physics of the University of Bologna a new intensified linear array detector is under development. The core of the system is a digital intensified CCD camera, the electron bombarded charge coupled device (EBCCD). The main innovation is a coherent rectangular-to-linear fiber optics adapter coupling the 1 in. diameter photocathode of the camera with a linear 129 mm × 1.45 mm strip of Gd2O2S:Tb. In this way a high spatial resolution over an extended length is obtained. The detector works as an X-ray scanner by means of a high-precision translation mechanical device to inspect a 13 cm × 18 cm area. A complete characterisation of the system has been made in terms of linearity, dynamic range, modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE). At last, radiographic tests on a set of samples have been made and will be presented.
2004
BETTUZZI M., CORNACCHIA S., ROSSI M., PALTRINIERI E., MORIGI M.P., BRANCACCIO R., et al. (2004). A NEW LINEAR ARRAY DETECTOR FOR HIGH RESOLUTION AND LOW DOSE DIGITAL RADIOGRAPHY. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 213, 227-230 [10.1016/S0168-583X(03)01577-5].
BETTUZZI M.; CORNACCHIA S.; ROSSI M.; PALTRINIERI E.; MORIGI M.P.; BRANCACCIO R.; ROMANI D.; CASALI F.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1197
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact