The treatment of giant, large, multiple or wide-necked carotid siphon aneurysms has always represented a challenge for neurosurgeons and neuroradiologists. Very recently the use of stents with tiny holes has been proposed by two companies: Balt Silk Stent in Europe and Pipeline in America. We have used the Silk stent on a few patients and describe our first case who now has an eleven. month follow-up. The carotid siphon presented three converging aneurysms sharing a very large common neck. The Silk stent (Balt Extrusion, Montmorency, France) was deployed through a 4F Balt introducer. The procedure was uneventful and very quick. As soon as the stent was positioned contrast medium stagnation was displayed within. the aneurysm. The patient's post-operative course was normal and she was discharged three days later in good health.

Leonardi M., Dall’Olio M., Princiotta C., Simonetti L. (2008). Treatment of carotid siphon aneurysms with a microcell stent. A case report. INTERVENTIONAL NEURORADIOLOGY, 14(4), 429-434.

Treatment of carotid siphon aneurysms with a microcell stent. A case report.

LEONARDI, MARCO;
2008

Abstract

The treatment of giant, large, multiple or wide-necked carotid siphon aneurysms has always represented a challenge for neurosurgeons and neuroradiologists. Very recently the use of stents with tiny holes has been proposed by two companies: Balt Silk Stent in Europe and Pipeline in America. We have used the Silk stent on a few patients and describe our first case who now has an eleven. month follow-up. The carotid siphon presented three converging aneurysms sharing a very large common neck. The Silk stent (Balt Extrusion, Montmorency, France) was deployed through a 4F Balt introducer. The procedure was uneventful and very quick. As soon as the stent was positioned contrast medium stagnation was displayed within. the aneurysm. The patient's post-operative course was normal and she was discharged three days later in good health.
2008
Leonardi M., Dall’Olio M., Princiotta C., Simonetti L. (2008). Treatment of carotid siphon aneurysms with a microcell stent. A case report. INTERVENTIONAL NEURORADIOLOGY, 14(4), 429-434.
Leonardi M.; Dall’Olio M.; Princiotta C.; Simonetti L.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/115499
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 15
social impact