Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
CRIS Current Research Information System
The neutron-induced fission cross section of 245Cm was measured at n_TOF in a wide energy range and with high resolution. The energy dependence, measured in a single measurement from 30 meV to 1 MeV neutron energy, has been determined with 5% accuracy relative to the 235U(n,f) cross section. In order to reduce the uncertainty on the absolute value, the data have been normalized at thermal energy to recent measurements performed at ILL and BR1. In the energy range of overlap, the results are in fair agreement with some previous measurements and confirm, on average, the evaluated cross section in the ENDF/B-VII.0 database, although sizable differences are observed for some important resonances below 20 eV. A similar behavior is observed relative to JENDL/AC-2008, a reactor-oriented database for actinides. The new results contribute to the overall improvement of the databases needed for the design of advanced reactor systems and may lead to refinements of fission models for the actinides.
Calviani M., Meaze M. H., Colonna N., Praena J., Abbondanno U., Aerts G., et al. (2012). Neutron-induced fission cross section of 245Cm: New results from data taken at the time-of-flight facility n_TOF. PHYSICAL REVIEW. C, NUCLEAR PHYSICS, 85, 034616-1-034616-10 [10.1103/PhysRevC.85.034616].
Neutron-induced fission cross section of 245Cm: New results from data taken at the time-of-flight facility n_TOF
The neutron-induced fission cross section of 245Cm was measured at n_TOF in a wide energy range and with high resolution. The energy dependence, measured in a single measurement from 30 meV to 1 MeV neutron energy, has been determined with 5% accuracy relative to the 235U(n,f) cross section. In order to reduce the uncertainty on the absolute value, the data have been normalized at thermal energy to recent measurements performed at ILL and BR1. In the energy range of overlap, the results are in fair agreement with some previous measurements and confirm, on average, the evaluated cross section in the ENDF/B-VII.0 database, although sizable differences are observed for some important resonances below 20 eV. A similar behavior is observed relative to JENDL/AC-2008, a reactor-oriented database for actinides. The new results contribute to the overall improvement of the databases needed for the design of advanced reactor systems and may lead to refinements of fission models for the actinides.
Calviani M., Meaze M. H., Colonna N., Praena J., Abbondanno U., Aerts G., et al. (2012). Neutron-induced fission cross section of 245Cm: New results from data taken at the time-of-flight facility n_TOF. PHYSICAL REVIEW. C, NUCLEAR PHYSICS, 85, 034616-1-034616-10 [10.1103/PhysRevC.85.034616].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/115124
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
21
14
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.