Dissipative systems have widely proven their effectiveness in mitigating seismic effects in structures, as they are easily applicable and they reduce the kinetic energy transferred by earthquakes to structures. Still the issue is open in terms of identifying the additional damper system that maximizes the overall dissipative properties of the structure under a wide range of dynamic inputs and with reference to a number of performance indexes. The research here presented starts from the results of the latest studies about the optimal dampers placement inside structures, to identify an innovative damping system composed by hysterethic dampers. The analysis concern the structural dynamic assessment of an existing structure (Corpo D of Ospedale Maggiore in Bologna, Italy), composed of a central non moment-resisting steel frame characterized by a small horizontal stiffness, which supports essentially the vertical actions, and two external lateral-resisting elements of reinforced concrete (concrete cores) which mainly support the horizontal loads. The corresponding storeys of the two portions of the building (i.e. the frame structure and the lateral-resisting elements) are linked with appropriate metallic sinusoidal elements, whose non linear behavior is here analyzed.

Utilizzo di link dissipativi isteretici per la mitigazione degli effetti del sisma: valutazione del comportamento strutturale del Corpo D dell'Ospedale Maggiore di Bologna / T. Trombetti; G. Gasparini; S. Silvestri; L. Bacci. - ELETTRONICO. - (2011), pp. xxx-xxx. (Intervento presentato al convegno XXIII Congresso C.T.A., Giornate italiane della costruzione in acciaio tenutosi a Lacco Ameno, Ischia (NA) nel 09-12 ottobre 2011).

Utilizzo di link dissipativi isteretici per la mitigazione degli effetti del sisma: valutazione del comportamento strutturale del Corpo D dell'Ospedale Maggiore di Bologna

TROMBETTI, TOMASO;GASPARINI, GIADA;SILVESTRI, STEFANO;BACCI, LORENZO
2011

Abstract

Dissipative systems have widely proven their effectiveness in mitigating seismic effects in structures, as they are easily applicable and they reduce the kinetic energy transferred by earthquakes to structures. Still the issue is open in terms of identifying the additional damper system that maximizes the overall dissipative properties of the structure under a wide range of dynamic inputs and with reference to a number of performance indexes. The research here presented starts from the results of the latest studies about the optimal dampers placement inside structures, to identify an innovative damping system composed by hysterethic dampers. The analysis concern the structural dynamic assessment of an existing structure (Corpo D of Ospedale Maggiore in Bologna, Italy), composed of a central non moment-resisting steel frame characterized by a small horizontal stiffness, which supports essentially the vertical actions, and two external lateral-resisting elements of reinforced concrete (concrete cores) which mainly support the horizontal loads. The corresponding storeys of the two portions of the building (i.e. the frame structure and the lateral-resisting elements) are linked with appropriate metallic sinusoidal elements, whose non linear behavior is here analyzed.
2011
Atti del XXIII Congresso C.T.A., Giornate italiane della costruzione in acciaio
xxx
xxx
Utilizzo di link dissipativi isteretici per la mitigazione degli effetti del sisma: valutazione del comportamento strutturale del Corpo D dell'Ospedale Maggiore di Bologna / T. Trombetti; G. Gasparini; S. Silvestri; L. Bacci. - ELETTRONICO. - (2011), pp. xxx-xxx. (Intervento presentato al convegno XXIII Congresso C.T.A., Giornate italiane della costruzione in acciaio tenutosi a Lacco Ameno, Ischia (NA) nel 09-12 ottobre 2011).
T. Trombetti; G. Gasparini; S. Silvestri; L. Bacci
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/113844
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact