Fitek cementless cups have been adopted in our department in 1989. The first 100 consecutive Fitek implants were analyzed clinically (Harris hip score) and radiographically (anteroposterior and lateral x-rays) with a mean follow-up of 9.7 years. We did not have any case of cup loosening or any other problem requiring cup revision. In this series, we had 86 excellent, 10 good, 2 fair, and 2 poor results. The 2 poor results were because of 2 cases of aseptic loosening of the stem (1 cemented and 1 cementless). The x-rays showed an average angle of cup inclination of 36.5° (range 16°-54°) after surgery and no variations at the last follow-up. Bidimensional linear wear of the acetabular component showed 6 cases of measurable wear with an average wear rate per year of 0.265 mm. The overall wear rate per year was 0.02 mm. At the time of the last follow-up examination, we had 3 femoral osteolysis and no case of acetabular osteolysis. In our series, we observed "lack of contact" zones above the polar depression in 71 cases immediately after surgery. The average thickness of these lines was 1 (range 0.5-3.5) mm. Of these, at the last follow-up, 61 cases (86%) showed a complete "filling" of the "lack of contact," whereas in 10 (24%), the "filling" was incomplete (4 cases still showing a radiolucent line [≤0.5 mm] in zone II). In the first group with "complete filling," we found 23 (37%) cases with bone ingrowth and no migration of the cup, whereas 38 (63%) cases showed bone ingrowth with evidence of cup migration. The Mann-Whitney nonparametric U test and the Kruskal-Wallis test showed that the survival rate of the 100 analyzed cups, after a follow-up time of 9.7 years, was 100% (end point: revision for any cause). Fitek cup showed good clinicoradiographic results

Long-term results with cementless Fitek (or Fitmore) cups / Marchetti P; Binazzi R; Vaccari V; Girolami M; Morici F; Impallomeni C; Commessatti M; Silvello L.. - In: THE JOURNAL OF ARTHROPLASTY. - ISSN 0883-5403. - STAMPA. - 20(6):(2005), pp. 730-737. [10.1016/j.arth.2004.11.019]

Long-term results with cementless Fitek (or Fitmore) cups.

VACCARI, VITTORIO;
2005

Abstract

Fitek cementless cups have been adopted in our department in 1989. The first 100 consecutive Fitek implants were analyzed clinically (Harris hip score) and radiographically (anteroposterior and lateral x-rays) with a mean follow-up of 9.7 years. We did not have any case of cup loosening or any other problem requiring cup revision. In this series, we had 86 excellent, 10 good, 2 fair, and 2 poor results. The 2 poor results were because of 2 cases of aseptic loosening of the stem (1 cemented and 1 cementless). The x-rays showed an average angle of cup inclination of 36.5° (range 16°-54°) after surgery and no variations at the last follow-up. Bidimensional linear wear of the acetabular component showed 6 cases of measurable wear with an average wear rate per year of 0.265 mm. The overall wear rate per year was 0.02 mm. At the time of the last follow-up examination, we had 3 femoral osteolysis and no case of acetabular osteolysis. In our series, we observed "lack of contact" zones above the polar depression in 71 cases immediately after surgery. The average thickness of these lines was 1 (range 0.5-3.5) mm. Of these, at the last follow-up, 61 cases (86%) showed a complete "filling" of the "lack of contact," whereas in 10 (24%), the "filling" was incomplete (4 cases still showing a radiolucent line [≤0.5 mm] in zone II). In the first group with "complete filling," we found 23 (37%) cases with bone ingrowth and no migration of the cup, whereas 38 (63%) cases showed bone ingrowth with evidence of cup migration. The Mann-Whitney nonparametric U test and the Kruskal-Wallis test showed that the survival rate of the 100 analyzed cups, after a follow-up time of 9.7 years, was 100% (end point: revision for any cause). Fitek cup showed good clinicoradiographic results
2005
Long-term results with cementless Fitek (or Fitmore) cups / Marchetti P; Binazzi R; Vaccari V; Girolami M; Morici F; Impallomeni C; Commessatti M; Silvello L.. - In: THE JOURNAL OF ARTHROPLASTY. - ISSN 0883-5403. - STAMPA. - 20(6):(2005), pp. 730-737. [10.1016/j.arth.2004.11.019]
Marchetti P; Binazzi R; Vaccari V; Girolami M; Morici F; Impallomeni C; Commessatti M; Silvello L.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/113808
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 35
  • Scopus 87
  • ???jsp.display-item.citation.isi??? 80
social impact