Total knee replacement designs claim characteristic kinematic performance that is rarely assessed in patients. In the present study, in vivo kinematics of a new prosthesis design was measured during activities of daily living. This design is posterior stabilized for which spine-cam interaction coordinates free axial rotation throughout the flexion-extension arc by means of a single radius of curvature for the femoral condyles in the sagittal and frontal planes. Fifteen knees were implanted with this prosthesis, and 3D video-fluoroscopic analysis was performed at 6-month follow-up for three motor tasks. The average range of flexion was 70.1° (range: 60.1-80.2°) during stair-climbing, 74.7° (64.6-84.8°) during chair-rising, and 64.1° (52.9-74.3°) during step-up. The corresponding average rotation on the tibial base-plate of the lines between the medial and lateral contact points was 9.4° (4.0-22.4°), 11.4° (4.6-22.7°), and 11.3° (5.1-18.0°), respectively. The pivot point for these lines was found mostly in the central area of the base-plate. Nearly physiological range of axial rotation can be achieved at the replaced knee during activities of daily living

In-vivo knee kinematics in rotationally unconstrained total knee arthroplasty / Catani F.; Belvedere C.; Ensini A.; Feliciangeli A.; Giannini S.; Leardini A.. - In: JOURNAL OF ORTHOPAEDIC RESEARCH. - ISSN 0736-0266. - STAMPA. - 29:(2011), pp. 1484-1490. [10.1002/jor.21397]

In-vivo knee kinematics in rotationally unconstrained total knee arthroplasty.

CATANI, FABIO;GIANNINI, SANDRO;
2011

Abstract

Total knee replacement designs claim characteristic kinematic performance that is rarely assessed in patients. In the present study, in vivo kinematics of a new prosthesis design was measured during activities of daily living. This design is posterior stabilized for which spine-cam interaction coordinates free axial rotation throughout the flexion-extension arc by means of a single radius of curvature for the femoral condyles in the sagittal and frontal planes. Fifteen knees were implanted with this prosthesis, and 3D video-fluoroscopic analysis was performed at 6-month follow-up for three motor tasks. The average range of flexion was 70.1° (range: 60.1-80.2°) during stair-climbing, 74.7° (64.6-84.8°) during chair-rising, and 64.1° (52.9-74.3°) during step-up. The corresponding average rotation on the tibial base-plate of the lines between the medial and lateral contact points was 9.4° (4.0-22.4°), 11.4° (4.6-22.7°), and 11.3° (5.1-18.0°), respectively. The pivot point for these lines was found mostly in the central area of the base-plate. Nearly physiological range of axial rotation can be achieved at the replaced knee during activities of daily living
2011
In-vivo knee kinematics in rotationally unconstrained total knee arthroplasty / Catani F.; Belvedere C.; Ensini A.; Feliciangeli A.; Giannini S.; Leardini A.. - In: JOURNAL OF ORTHOPAEDIC RESEARCH. - ISSN 0736-0266. - STAMPA. - 29:(2011), pp. 1484-1490. [10.1002/jor.21397]
Catani F.; Belvedere C.; Ensini A.; Feliciangeli A.; Giannini S.; Leardini A.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/113243
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 21
social impact