A four-shell head phantom has been built and characterized. Its structure is similar to that of nonhomogeneous concentric shell domains used by numerical solvers that better approximate current distribution than phantoms currently used to validateelectrical impedance tomography systems. Each shell represents a head tissue, namely, skin, skull, cerebrospinal fluid, and brain. A novel technique, which employs a volume conductive impermeable film, has been implemented to prevent ion diffusion between different agar regions without affecting current distribution inside the phantom. Comparisons between simulations and phantom measurements performed over four days are given to prove both the adherence to the model in the frequency range between 10 kHz and 1 MHz and its long-term stability.

M. Sperandio, M. Guermandi, R. Guerrieri (2012). A Four-Shell Diffusion Phantom of the Head for Electrical Impedance Tomography. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 59, no.2, February 2012, 383-389 [10.1109/TBME.2011.2173197].

A Four-Shell Diffusion Phantom of the Head for Electrical Impedance Tomography

GUERMANDI, MARCO;GUERRIERI, ROBERTO
2012

Abstract

A four-shell head phantom has been built and characterized. Its structure is similar to that of nonhomogeneous concentric shell domains used by numerical solvers that better approximate current distribution than phantoms currently used to validateelectrical impedance tomography systems. Each shell represents a head tissue, namely, skin, skull, cerebrospinal fluid, and brain. A novel technique, which employs a volume conductive impermeable film, has been implemented to prevent ion diffusion between different agar regions without affecting current distribution inside the phantom. Comparisons between simulations and phantom measurements performed over four days are given to prove both the adherence to the model in the frequency range between 10 kHz and 1 MHz and its long-term stability.
2012
M. Sperandio, M. Guermandi, R. Guerrieri (2012). A Four-Shell Diffusion Phantom of the Head for Electrical Impedance Tomography. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 59, no.2, February 2012, 383-389 [10.1109/TBME.2011.2173197].
M. Sperandio; M. Guermandi; R. Guerrieri
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/111909
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 16
social impact