Clinical hearing assessments should aim to quantify children's listening abilities in everyday environments, par ticularly classrooms, which are critical for academic success. In practice, however, conventional assessments typically rely on anechoic speech stimuli presented under highly controlled conditions, which may not cap ture the acoustic complexity of real classrooms. This study examined whether auralized classroom simulations can improve the ecological validity of speech intelligibility assessments in children. Twenty-eight primary school children with normal hearing (grades 4-5, ages 9-11) completed the Word Intelligibility by Picture Identification test in three listening environments: a real classroom, a clinical setting with anechoic speech stimuli delivered through headphones, and an auralized classroom simulation delivered through headphones. Speech intelligibility was assessed at three signal-to-noise ratios representative of typical classroom listening conditions, and all par ticipants were tested in each listening environment. At the reference SNR (0 dB), intelligibility was significantly higher in both the clinical and auralized conditions than in the real classroom, whereas performance did not differ significantly between the clinical and auralized conditions. Increasing SNR produced comparable benefits in the real and auralized classrooms, but a significantly smaller benefit in the clinic. Moreover, auralized performance contributed significantly to the prediction of real-classroom responses beyond that provided by conventional clinical performance. Although auralization did not fully reproduce in-situ classroom performance, it captured SNR-related changes similarly to the real classroom and provided information about classroom intelligibility that was not captured by conventional clinical scores. Auralized testing may therefore complement standard clinical assessment by providing a more ecologically relevant characterization of children's speech perception.

Tardini, V., Fusari, G., Bottalico, P. (2027). Speech intelligibility in classrooms, clinical, and auralized environments: Comparing listening performance in primary school children. APPLIED ACOUSTICS, 257, 1-10 [10.1016/j.apacoust.2026.111629].

Speech intelligibility in classrooms, clinical, and auralized environments: Comparing listening performance in primary school children

Tardini V.;Bottalico P.
2027

Abstract

Clinical hearing assessments should aim to quantify children's listening abilities in everyday environments, par ticularly classrooms, which are critical for academic success. In practice, however, conventional assessments typically rely on anechoic speech stimuli presented under highly controlled conditions, which may not cap ture the acoustic complexity of real classrooms. This study examined whether auralized classroom simulations can improve the ecological validity of speech intelligibility assessments in children. Twenty-eight primary school children with normal hearing (grades 4-5, ages 9-11) completed the Word Intelligibility by Picture Identification test in three listening environments: a real classroom, a clinical setting with anechoic speech stimuli delivered through headphones, and an auralized classroom simulation delivered through headphones. Speech intelligibility was assessed at three signal-to-noise ratios representative of typical classroom listening conditions, and all par ticipants were tested in each listening environment. At the reference SNR (0 dB), intelligibility was significantly higher in both the clinical and auralized conditions than in the real classroom, whereas performance did not differ significantly between the clinical and auralized conditions. Increasing SNR produced comparable benefits in the real and auralized classrooms, but a significantly smaller benefit in the clinic. Moreover, auralized performance contributed significantly to the prediction of real-classroom responses beyond that provided by conventional clinical performance. Although auralization did not fully reproduce in-situ classroom performance, it captured SNR-related changes similarly to the real classroom and provided information about classroom intelligibility that was not captured by conventional clinical scores. Auralized testing may therefore complement standard clinical assessment by providing a more ecologically relevant characterization of children's speech perception.
2027
Tardini, V., Fusari, G., Bottalico, P. (2027). Speech intelligibility in classrooms, clinical, and auralized environments: Comparing listening performance in primary school children. APPLIED ACOUSTICS, 257, 1-10 [10.1016/j.apacoust.2026.111629].
Tardini, V.; Fusari, G.; Bottalico, P.
File in questo prodotto:
File Dimensione Formato  
Speech intelligibility in classrooms, clinical, and auralized environments Comparing listening performance in primary school children.pdf

accesso aperto

Tipo: Versione (PDF) editoriale / Version Of Record
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 2.28 MB
Formato Adobe PDF
2.28 MB Adobe PDF Visualizza/Apri
1-s2.0-S0003682X26004111-mmc1.pdf

accesso aperto

Tipo: File Supplementare
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 110.69 kB
Formato Adobe PDF
110.69 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1093971
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
  • OpenAlex ND
social impact