Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
CRIS Current Research Information System
The neutron-induced fission cross section of 236U was measured at the neutron Time-of-Flight (n_TOF) facility at CERN relative to the standard 235U(n,f) cross section for neutron energies ranging from above thermal to several MeV. The measurement, covering the full range simultaneously, was performed with a fast ionization chamber, taking advantage of the high resolution of the n_TOF spectrometer. The n_TOF results confirm that the first resonance at 5.45 eV is largely overestimated in some nuclear data libraries. The resonance triplet around 1.2 keV was measured with high resolution and resonance parameters were determined with good accuracy. Resonances at high energy have also been observed and characterized and different values for the cross section are provided for the region between 10 keV and the fission threshold. The present work indicates various shortcomings of the current nuclear data libraries in the subthreshold region and provides the basis for an accurate re-evaluation of the 236U(n,f) cross section, which is of great relevance for the development of emerging or innovative nuclear reactor technologies.
R. Sarmento, M. Calviani, J. Praena, N. Colonna, F. Belloni, I. F. Gonçalves, et al. (2011). Measurement of the 236U(n,f) cross section from 170 meV to 2 MeV at the CERN n_TOF facility. PHYSICAL REVIEW. C, NUCLEAR PHYSICS, 84, 044618-1-044618-10 [10.1103/PhysRevC.84.044618].
Measurement of the 236U(n,f) cross section from 170 meV to 2 MeV at the CERN n_TOF facility
The neutron-induced fission cross section of 236U was measured at the neutron Time-of-Flight (n_TOF) facility at CERN relative to the standard 235U(n,f) cross section for neutron energies ranging from above thermal to several MeV. The measurement, covering the full range simultaneously, was performed with a fast ionization chamber, taking advantage of the high resolution of the n_TOF spectrometer. The n_TOF results confirm that the first resonance at 5.45 eV is largely overestimated in some nuclear data libraries. The resonance triplet around 1.2 keV was measured with high resolution and resonance parameters were determined with good accuracy. Resonances at high energy have also been observed and characterized and different values for the cross section are provided for the region between 10 keV and the fission threshold. The present work indicates various shortcomings of the current nuclear data libraries in the subthreshold region and provides the basis for an accurate re-evaluation of the 236U(n,f) cross section, which is of great relevance for the development of emerging or innovative nuclear reactor technologies.
R. Sarmento, M. Calviani, J. Praena, N. Colonna, F. Belloni, I. F. Gonçalves, et al. (2011). Measurement of the 236U(n,f) cross section from 170 meV to 2 MeV at the CERN n_TOF facility. PHYSICAL REVIEW. C, NUCLEAR PHYSICS, 84, 044618-1-044618-10 [10.1103/PhysRevC.84.044618].
R. Sarmento; M. Calviani; J. Praena; N. Colonna; F. Belloni; I. F. Gonçalves; P. Vaz; G. Aerts; H. Alvarez; F. Alvarez-Velarde; S. Andriamonje; J. And...espandi
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/107468
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
21
16
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.