Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
CRIS Current Research Information System
We develop techniques for generating accurate and precise internal covariances for measurements of clustering and weak-lensing angular power spectra. These methods have been designed to produce non-singular and unbiased covariances for Euclid's large anticipated data vector and will be critical for validation against observational systematic effects. We constructed jackknife segments that are equal in area to a high precision by adapting the binary space partition algorithm to work on arbitrarily shaped regions on the unit sphere. Jackknife estimates of the covariances are internally derived and require no assumptions about cosmology or galaxy population and bias. Our covariance estimation, called DICES (Debiased Internal Covariance Estimation with Shrinkage), first estimated a noisy covariance through conventional delete-1 jackknife resampling. This was followed by linear shrinkage of the empirical correlation matrix towards the Gaussian prediction, rather than linear shrinkage of the covariance matrix. Shrinkage ensures the covariance is non-singular and therefore invertible, which is critical for the estimation of likelihoods and validation. We then applied a delete-2 jackknife bias correction to the diagonal components of the jackknife covariance that removed the general tendency for jackknife error estimates to be biased high. We validated internally derived covariances, which used the jackknife resampling technique, on synthetic Euclid-like lognormal catalogues. We demonstrate that DICES produces accurate, non-singular covariance estimates, with the relative error improving by 33% for the covariance and 48% for the correlation structure in comparison to jackknife estimates. These estimates can be used for highly accurate regression and inference.
Naidoo, K., Ruiz-Zapatero, J., Tessore, N., Joachimi, B., Loureiro, A., Aghanim, N., et al. (2026). Euclid preparation LXXXIX. Accurate and precise data-driven angular power spectrum covariances. ASTRONOMY & ASTROPHYSICS, 708, 1-20 [10.1051/0004-6361/202555893].
Euclid preparation LXXXIX. Accurate and precise data-driven angular power spectrum covariances
We develop techniques for generating accurate and precise internal covariances for measurements of clustering and weak-lensing angular power spectra. These methods have been designed to produce non-singular and unbiased covariances for Euclid's large anticipated data vector and will be critical for validation against observational systematic effects. We constructed jackknife segments that are equal in area to a high precision by adapting the binary space partition algorithm to work on arbitrarily shaped regions on the unit sphere. Jackknife estimates of the covariances are internally derived and require no assumptions about cosmology or galaxy population and bias. Our covariance estimation, called DICES (Debiased Internal Covariance Estimation with Shrinkage), first estimated a noisy covariance through conventional delete-1 jackknife resampling. This was followed by linear shrinkage of the empirical correlation matrix towards the Gaussian prediction, rather than linear shrinkage of the covariance matrix. Shrinkage ensures the covariance is non-singular and therefore invertible, which is critical for the estimation of likelihoods and validation. We then applied a delete-2 jackknife bias correction to the diagonal components of the jackknife covariance that removed the general tendency for jackknife error estimates to be biased high. We validated internally derived covariances, which used the jackknife resampling technique, on synthetic Euclid-like lognormal catalogues. We demonstrate that DICES produces accurate, non-singular covariance estimates, with the relative error improving by 33% for the covariance and 48% for the correlation structure in comparison to jackknife estimates. These estimates can be used for highly accurate regression and inference.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1063652
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
ND
0
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.