With the improvement of living standards, there is an increasing focus on individual health conditions. Benefiting from technological advancements, non-contact physiological detection methods based on facial videos have transitioned from laboratory settings to everyday life. Due to its convenience, non-invasiveness, and contactless nature, this method exhibits extensive prospects. This paper presents the design and implementation of a remote vital signs monitoring system characterized by portability, real-time data collection, data processing and analysis, as well as storage capabilities. Multiple sensor circuits are meticulously designed, and factors influencing the accuracy of Remote Photoplethysmography (rPPG) are compared and analyzed. The paper also outlines the key directions for noise removal algorithms to enhance accuracy.

Tian, Z., Chen, Q., Peng, J., Zang, D., Feng, M., Su, W. (2024). Design of Portable Non-contact Physiological Data Acquisition System. Association for Computing Machinery [10.1145/3647722.3647728].

Design of Portable Non-contact Physiological Data Acquisition System

Chen, Qian;
2024

Abstract

With the improvement of living standards, there is an increasing focus on individual health conditions. Benefiting from technological advancements, non-contact physiological detection methods based on facial videos have transitioned from laboratory settings to everyday life. Due to its convenience, non-invasiveness, and contactless nature, this method exhibits extensive prospects. This paper presents the design and implementation of a remote vital signs monitoring system characterized by portability, real-time data collection, data processing and analysis, as well as storage capabilities. Multiple sensor circuits are meticulously designed, and factors influencing the accuracy of Remote Photoplethysmography (rPPG) are compared and analyzed. The paper also outlines the key directions for noise removal algorithms to enhance accuracy.
2024
ACM International Conference Proceeding Series
35
41
Tian, Z., Chen, Q., Peng, J., Zang, D., Feng, M., Su, W. (2024). Design of Portable Non-contact Physiological Data Acquisition System. Association for Computing Machinery [10.1145/3647722.3647728].
Tian, Zandong; Chen, Qian; Peng, Jiahe; Zang, Dongyuan; Feng, Mianshi; Su, Weihua
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1051318
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact