In recent years, Transcranial Color Doppler (TCCD) has gained increasing recognition as a non-invasive neuromonitoring tool. However, there remains a strong tendency to view arterial TCCD as the ‘stethoscope for the brain,’ while the assessment of cerebral venous flow is still underrepresented in clinical protocols. This review aims to explore the emerging role of venous TCCD, particularly when combined with Internal Jugular Vein (IJV) ultrasound, in evaluating cerebral venous outflow in both critically ill and surgical patients. We conducted a narrative review of e-Pub articles from PubMed, MEDLINE, and Scopus, on the pathophysiological factors that impair cerebral venous drainage and their clinical implications in surgical and critical care settings. Based on this evidence, we developed two procedural algorithms that integrate established knowledge of cerebral venous hemodynamics with common clinical conditions affecting venous outflow, including internal jugular central venous catheter placement, mechanical ventilation, and pneumoperitoneum. The algorithms emphasize systematic monitoring of cerebral venous drainage, including assessment of internal jugular vein morphology and Rosenthal’s vein flow, to guide procedural optimization and minimize potential neurological complications. They were informed by validated frameworks, such as the RaCeVa protocol, and are illustrated through two representative clinical case scenarios. Cerebral venous congestion can be induced by multiple established risk factors, including mechanical ventilation, cardiovascular disease, elevated intra-abdominal pressure, the Trendelenburg position, and central venous catheterization. In selected patients, real-time venous TCCD monitoring, combined with IJV assessment, allows early detection of cerebral venous outflow impairment and guides timely hemodynamic and procedural adjustments in both surgical settings and critical care contexts. Venous TCCD neuromonitoring may help prevent intracranial hypertension and its consequent neurological complications. It can guide clinical decisions during procedures that may compromise cerebral venous drainage, such as mechanical ventilation, the placement of large-bore central venous catheters, or laparoscopic and robot-assisted surgeries. Further studies are warranted to validate this strategy and better define its role in specific high-risk clinical scenarios.

Bianchini, A., Vitale, G., Melegari, G., Cescon, M., Ravaioli, M., Zangheri, E., et al. (2026). Transcranial Color Doppler for Assessing Cerebral Venous Outflow in Critically Ill and Surgical Patients. DIAGNOSTICS, 16(2), 1-16 [10.3390/diagnostics16020289].

Transcranial Color Doppler for Assessing Cerebral Venous Outflow in Critically Ill and Surgical Patients

Bianchini A.;Vitale G.
;
Cescon M.;Ravaioli M.;Scuppa M. F.;Siniscalchi A.
2026

Abstract

In recent years, Transcranial Color Doppler (TCCD) has gained increasing recognition as a non-invasive neuromonitoring tool. However, there remains a strong tendency to view arterial TCCD as the ‘stethoscope for the brain,’ while the assessment of cerebral venous flow is still underrepresented in clinical protocols. This review aims to explore the emerging role of venous TCCD, particularly when combined with Internal Jugular Vein (IJV) ultrasound, in evaluating cerebral venous outflow in both critically ill and surgical patients. We conducted a narrative review of e-Pub articles from PubMed, MEDLINE, and Scopus, on the pathophysiological factors that impair cerebral venous drainage and their clinical implications in surgical and critical care settings. Based on this evidence, we developed two procedural algorithms that integrate established knowledge of cerebral venous hemodynamics with common clinical conditions affecting venous outflow, including internal jugular central venous catheter placement, mechanical ventilation, and pneumoperitoneum. The algorithms emphasize systematic monitoring of cerebral venous drainage, including assessment of internal jugular vein morphology and Rosenthal’s vein flow, to guide procedural optimization and minimize potential neurological complications. They were informed by validated frameworks, such as the RaCeVa protocol, and are illustrated through two representative clinical case scenarios. Cerebral venous congestion can be induced by multiple established risk factors, including mechanical ventilation, cardiovascular disease, elevated intra-abdominal pressure, the Trendelenburg position, and central venous catheterization. In selected patients, real-time venous TCCD monitoring, combined with IJV assessment, allows early detection of cerebral venous outflow impairment and guides timely hemodynamic and procedural adjustments in both surgical settings and critical care contexts. Venous TCCD neuromonitoring may help prevent intracranial hypertension and its consequent neurological complications. It can guide clinical decisions during procedures that may compromise cerebral venous drainage, such as mechanical ventilation, the placement of large-bore central venous catheters, or laparoscopic and robot-assisted surgeries. Further studies are warranted to validate this strategy and better define its role in specific high-risk clinical scenarios.
2026
Bianchini, A., Vitale, G., Melegari, G., Cescon, M., Ravaioli, M., Zangheri, E., et al. (2026). Transcranial Color Doppler for Assessing Cerebral Venous Outflow in Critically Ill and Surgical Patients. DIAGNOSTICS, 16(2), 1-16 [10.3390/diagnostics16020289].
Bianchini, A.; Vitale, G.; Melegari, G.; Cescon, M.; Ravaioli, M.; Zangheri, E.; Scuppa, M. F.; Tigano, S.; Siniscalchi, A.
File in questo prodotto:
File Dimensione Formato  
diagnostics-16-00289.pdf

accesso aperto

Tipo: Versione (PDF) editoriale / Version Of Record
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 2.09 MB
Formato Adobe PDF
2.09 MB Adobe PDF Visualizza/Apri
diagnostics-16-00289-s001.zip

accesso aperto

Tipo: File Supplementare
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 28.89 MB
Formato Zip File
28.89 MB Zip File Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1048990
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact