We present a detailed and insightful analysis of the transient response of chemo-resistive MOX gas sensors and we propose an innovative strategy to reduce by 20x the power used to perform a measurement at the cost of a fixed reading interval. Our approach is targeted to continuous and autonomous environmental monitoring applications, for example in Wireless Gas Sensor Networks (WGSN). We apply the proposed technique to MOX sensors targeted to methane with a reading rate of 60sec. This technique can be easily adapted to e-Nose scenarios where multiple sensors are used, and higher measurement rates are required. Indeed, results demonstrate that it is possible to identify and measure from very-low (0, 1\%) to high (1\%) methane concentrations in air, taking into account also important parameters such as the environmental humidity, which strongly affects the sensor's behavior.

Rossi, M., Brunelli, D. (2013). Analyzing the transient response of MOX gas sensors to improve the lifetime of distributed sensing systems. USA : ACM/IEEE [10.1109/IWASI.2013.6576066].

Analyzing the transient response of MOX gas sensors to improve the lifetime of distributed sensing systems

Brunelli, Davide
Supervision
2013

Abstract

We present a detailed and insightful analysis of the transient response of chemo-resistive MOX gas sensors and we propose an innovative strategy to reduce by 20x the power used to perform a measurement at the cost of a fixed reading interval. Our approach is targeted to continuous and autonomous environmental monitoring applications, for example in Wireless Gas Sensor Networks (WGSN). We apply the proposed technique to MOX sensors targeted to methane with a reading rate of 60sec. This technique can be easily adapted to e-Nose scenarios where multiple sensors are used, and higher measurement rates are required. Indeed, results demonstrate that it is possible to identify and measure from very-low (0, 1\%) to high (1\%) methane concentrations in air, taking into account also important parameters such as the environmental humidity, which strongly affects the sensor's behavior.
2013
Advances in Sensors and Interfaces (IWASI), 2013 5th IEEE International Workshop on
211
216
Rossi, M., Brunelli, D. (2013). Analyzing the transient response of MOX gas sensors to improve the lifetime of distributed sensing systems. USA : ACM/IEEE [10.1109/IWASI.2013.6576066].
Rossi, Maurizio; Brunelli, Davide
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1043439
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 16
  • OpenAlex ND
social impact