Background and study aims Feasibility of EUS-guided choledochoduodenostomy (EUS-CDS) using available lumen-apposing stents (LAMS) is limited by the size of the common bile duct (CBD) (<= 12 mm, cut-off for experts: 15 mm, cut-off for non-experts). We aimed to assess the prevalence and predictive factors associated with CBD size >= 12 and 15mm in naive patients with malignant distal biliary obstruction (MDBO).Patients and methods This was a prospective cohort study involving 22 centers with assessment of CBD diameter and subjective feasibility of the EUS-CDS performance in naive jaundiced patients undergoing EUS evaluation for MDBO.Results A total of 491 patients (mean age 69 +/- 12 years) with mean serum bilirubin of 12.7 +/- 6.6 mg/dL entered the final analysis. Dilation of the CBD >= 12 and 15mm was detected in 78.8% and 51.9% of cases, respectively. Subjective feasibility of EUS-CDS was expressed by endosonographers in 91.2% for a CBD >= 12 mm and in 96.5% for a CBD >= 15 mm. On multivariate analysis, age (P<0.01) and bilirubin level (P <= 0.001) were the only factors associated with both CBD dilation >= 12 and >= 15 mm. These variables were poorly associated with the extent of duct dilation: however, based on them a prediction model could be constructed that satisfactorily predicted CBD size >= 12 mm in patients at least 70 years and a bilirubin level >= 7 mg/dL.Conclusions Our study showed that at presentation in a large cohort of patients with MDBO, EUS-CDS can be potentially performed in three quarters to half of cases by expert and less experienced endosonographers, respectively. Dedicated stents or devices with different designs able to overcome the limitations of existing electrocautery-enhanced LAMS for EUS-CDS are needed.

Rimbas, M., Anderloni, A., Napoléon, B., Seicean, A., Forti, E., Crinò, S.f., et al. (2021). Common bile duct size in malignant distal obstruction and lumen-apposing metal stents: a multicenter prospective study. ENDOSCOPY INTERNATIONAL OPEN, 09(11), E1801-E1810 [10.1055/a-1526-1208].

Common bile duct size in malignant distal obstruction and lumen-apposing metal stents: a multicenter prospective study

Crinò, SF;Fabbri, C;Fugazza, A;Fusaroli, P;Mutignani, M;Binda, C;Cominardi, A;
2021

Abstract

Background and study aims Feasibility of EUS-guided choledochoduodenostomy (EUS-CDS) using available lumen-apposing stents (LAMS) is limited by the size of the common bile duct (CBD) (<= 12 mm, cut-off for experts: 15 mm, cut-off for non-experts). We aimed to assess the prevalence and predictive factors associated with CBD size >= 12 and 15mm in naive patients with malignant distal biliary obstruction (MDBO).Patients and methods This was a prospective cohort study involving 22 centers with assessment of CBD diameter and subjective feasibility of the EUS-CDS performance in naive jaundiced patients undergoing EUS evaluation for MDBO.Results A total of 491 patients (mean age 69 +/- 12 years) with mean serum bilirubin of 12.7 +/- 6.6 mg/dL entered the final analysis. Dilation of the CBD >= 12 and 15mm was detected in 78.8% and 51.9% of cases, respectively. Subjective feasibility of EUS-CDS was expressed by endosonographers in 91.2% for a CBD >= 12 mm and in 96.5% for a CBD >= 15 mm. On multivariate analysis, age (P<0.01) and bilirubin level (P <= 0.001) were the only factors associated with both CBD dilation >= 12 and >= 15 mm. These variables were poorly associated with the extent of duct dilation: however, based on them a prediction model could be constructed that satisfactorily predicted CBD size >= 12 mm in patients at least 70 years and a bilirubin level >= 7 mg/dL.Conclusions Our study showed that at presentation in a large cohort of patients with MDBO, EUS-CDS can be potentially performed in three quarters to half of cases by expert and less experienced endosonographers, respectively. Dedicated stents or devices with different designs able to overcome the limitations of existing electrocautery-enhanced LAMS for EUS-CDS are needed.
2021
Rimbas, M., Anderloni, A., Napoléon, B., Seicean, A., Forti, E., Crinò, S.f., et al. (2021). Common bile duct size in malignant distal obstruction and lumen-apposing metal stents: a multicenter prospective study. ENDOSCOPY INTERNATIONAL OPEN, 09(11), E1801-E1810 [10.1055/a-1526-1208].
Rimbas, M; Anderloni, A; Napoléon, B; Seicean, A; Forti, E; Crinò, Sf; Tarantino, I; Arcidiacono, Pg; Fabbri, C; Rizzatti, G; Amato, A; Voiosu, T; Fug...espandi
File in questo prodotto:
File Dimensione Formato  
a-1526-1208.pdf

accesso aperto

Tipo: Versione (PDF) editoriale / Version Of Record
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale - Non opere derivate (CCBYNCND)
Dimensione 970.83 kB
Formato Adobe PDF
970.83 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1040292
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 23
social impact