A Monte Carlo simulation of a 50mm×50mm×4mm continuous crystal has been developed to investigate the correlation between the scintillation light width (σ) and the Depth of Interaction (DoI) within the crystal. Our studies are based on a LaBr3(Ce) crystal, in order to take advantage of its high light yield to reduce the statistic uncertainties on the estimators of the σ. The first one, the standard deviation of the light distribution, has demonstrated a poor, though linear, correlation to DoI, that is not experimentally detectable. Otherwise, the second estimator,N/I, is the ratio of the total number of photoelectrons to the maximum number of photoelectrons collected from a single anode, in a scintillation event. N/I has been found to have the best correlation to DoI, that provides 2 mm resolution.

R. Pani, S. Nourbakhsh, P. Pani, P. Bennati, R. Pellegrini, M.N. Cinti, et al. (2011). DoI position resolution in a continuous LaBr3(Ce) scintillation crystal for gamma-ray imaging. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 215, 324-327 [10.1016/j.nuclphysbps.2011.04.044].

DoI position resolution in a continuous LaBr3(Ce) scintillation crystal for gamma-ray imaging

NAVARRIA, FRANCESCO LUIGI;LO MEO, SERGIO;LANCONELLI, NICO;
2011

Abstract

A Monte Carlo simulation of a 50mm×50mm×4mm continuous crystal has been developed to investigate the correlation between the scintillation light width (σ) and the Depth of Interaction (DoI) within the crystal. Our studies are based on a LaBr3(Ce) crystal, in order to take advantage of its high light yield to reduce the statistic uncertainties on the estimators of the σ. The first one, the standard deviation of the light distribution, has demonstrated a poor, though linear, correlation to DoI, that is not experimentally detectable. Otherwise, the second estimator,N/I, is the ratio of the total number of photoelectrons to the maximum number of photoelectrons collected from a single anode, in a scintillation event. N/I has been found to have the best correlation to DoI, that provides 2 mm resolution.
2011
R. Pani, S. Nourbakhsh, P. Pani, P. Bennati, R. Pellegrini, M.N. Cinti, et al. (2011). DoI position resolution in a continuous LaBr3(Ce) scintillation crystal for gamma-ray imaging. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 215, 324-327 [10.1016/j.nuclphysbps.2011.04.044].
R. Pani; S. Nourbakhsh; P. Pani; P. Bennati; R. Pellegrini; M.N. Cinti; R. Scafè; B. Cassano; F. Navarria; S. Lo Meo; N. Lanconelli; G. Moschini; P. B...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/103938
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact