Contamination of environmental surfaces by nosocomial pathogens like Pseudomonas aeruginosa (P. aeruginosa), Staphylococcus aureus (S. aureus), and Enterococcus spp. poses significant health risks worldwide. However, gold-standard detection methods are too time-consuming and labor-intensive. This study aimed to optimize loop-mediated isothermal amplification (LAMP) as a rapid, innovative, and cost-effective approach, comparing its effectiveness with the gold-standard cultural method. Sterile surfaces (24 cm2) were contaminated in duplicate with different concentrations of P. aeruginosa, S. aureus, and Enterococcus faecalis (E. faecalis) reference stains. For each pair of contaminated surfaces, one was analyzed using the agar contact plate method (UNI EN 17141:2021), while the other was analyzed using LAMP, following three different pre-incubation times (three, six, and nine hours). The sensitivity and accuracy of LAMP for P. aeruginosa improved with longer incubation times, reaching a value of 1.00 at nine hours, while the specificity and positive predictive value (PPV) remained at 1.00 regardless of the incubation time. For S. aureus, LAMP achieved a sensitivity, specificity, accuracy, PPV, and negative predictive value (NPV) of 1.00 across all incubation times. Finally, for E. faecalis, sensitivity increased from 0.57 at three hours to 1.00 at six and nine hours, with a high specificity, accuracy, PPV, and NPV from six hours onwards. These findings showed that LAMP can be used as a rapid and reliable alternative to gold-standard methods for detecting pathogens on surfaces. The high sensitivity and specificity achieved, especially at six and nine hours of pre-incubation, suggested its use for real-time monitoring in healthcare settings. Further research in real-world environments is needed to confirm these findings.

Marino, F., Bonincontro, C., Caligaris, L., Bellucci, L., Derelitto, C., Girolamini, L., et al. (2025). Optimization of Loop-Mediated Isothermal Amplification (LAMP) for the Rapid Detection of Nosocomial Pathogens on Environmental Surfaces. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 26(13), 1-14 [10.3390/ijms26135933].

Optimization of Loop-Mediated Isothermal Amplification (LAMP) for the Rapid Detection of Nosocomial Pathogens on Environmental Surfaces

Caterina Bonincontro;Laura Caligaris;Letizia Bellucci;Carlo Derelitto;Luna Girolamini;Sandra Cristino
2025

Abstract

Contamination of environmental surfaces by nosocomial pathogens like Pseudomonas aeruginosa (P. aeruginosa), Staphylococcus aureus (S. aureus), and Enterococcus spp. poses significant health risks worldwide. However, gold-standard detection methods are too time-consuming and labor-intensive. This study aimed to optimize loop-mediated isothermal amplification (LAMP) as a rapid, innovative, and cost-effective approach, comparing its effectiveness with the gold-standard cultural method. Sterile surfaces (24 cm2) were contaminated in duplicate with different concentrations of P. aeruginosa, S. aureus, and Enterococcus faecalis (E. faecalis) reference stains. For each pair of contaminated surfaces, one was analyzed using the agar contact plate method (UNI EN 17141:2021), while the other was analyzed using LAMP, following three different pre-incubation times (three, six, and nine hours). The sensitivity and accuracy of LAMP for P. aeruginosa improved with longer incubation times, reaching a value of 1.00 at nine hours, while the specificity and positive predictive value (PPV) remained at 1.00 regardless of the incubation time. For S. aureus, LAMP achieved a sensitivity, specificity, accuracy, PPV, and negative predictive value (NPV) of 1.00 across all incubation times. Finally, for E. faecalis, sensitivity increased from 0.57 at three hours to 1.00 at six and nine hours, with a high specificity, accuracy, PPV, and NPV from six hours onwards. These findings showed that LAMP can be used as a rapid and reliable alternative to gold-standard methods for detecting pathogens on surfaces. The high sensitivity and specificity achieved, especially at six and nine hours of pre-incubation, suggested its use for real-time monitoring in healthcare settings. Further research in real-world environments is needed to confirm these findings.
2025
Marino, F., Bonincontro, C., Caligaris, L., Bellucci, L., Derelitto, C., Girolamini, L., et al. (2025). Optimization of Loop-Mediated Isothermal Amplification (LAMP) for the Rapid Detection of Nosocomial Pathogens on Environmental Surfaces. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 26(13), 1-14 [10.3390/ijms26135933].
Marino, Federica; Bonincontro, Caterina; Caligaris, Laura; Bellucci, Letizia; Derelitto, Carlo; Girolamini, Luna; Cristino, Sandra
File in questo prodotto:
File Dimensione Formato  
ijms-26-05933.pdf

accesso aperto

Tipo: Versione (PDF) editoriale / Version Of Record
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 280.38 kB
Formato Adobe PDF
280.38 kB Adobe PDF Visualizza/Apri
ijms-26-05933-s001.zip

accesso aperto

Tipo: File Supplementare
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 274.44 kB
Formato Zip File
274.44 kB Zip File Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1038917
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
  • OpenAlex ND
social impact