OBJECTIVES This study sought to determine predictors of advanced conduction disturbances requiring late (>= 48 h) permanent pacemaker replacement (PPM) after transcatheter aortic valve replacement (TAVR). METHODS Data of consecutive patients were identified by retrospective review of a TAVR database of a single center in Milan, Italy, between October 2007 and July 2015. We defined delta PR (Delta PR) and delta QRS (Delta QRS) interval as the difference between the last PR and QRS length available 48 h after TAVR and the baseline PR and QRS length. RESULTS Overall population included 740 patients. We excluded 78 patients who already had a PPM and 51 patients who received a PPM < 48 h after TAVR. The final analysis included 611 patients. Fifty-four patients (8.8%) developed an advanced conduction disturbance requiring PPM >= 48 h following TAVR. Patients who required a late PPM implant had a wider QRS width (113 +/- 25 ms vs. 105 +/- 23 ms; p = 0.009) and a higher prevalence of baseline right bundle branch block (12.9% vs. 5.3%; p = 0.026) and were more likely to have a self-expandable valve implanted (51.8% vs. 31.9%; p = 0.003). The Delta PR was 40 +/- 51 ms (p = 0.0001) and the Delta QRS was 22 +/- 61 ms (p = 0.001). Multivariable analysis revealed that baseline right bundle branch block (odds ratio: 3.56; 95% confidence interval: 1.07 to 11.77; p = 0.037) and Delta PR (odds ratio for each 10-ms increase: 1.31; 95% confidence interval: 1.18 to 1.45; p = 0.0001) are independent predictors of delayed advanced conduction disturbances. CONCLUSIONS This analysis showed that baseline right bundle branch block and the amount of increase of PR length after TAVR are independent predictors of late (>= 48 h) advanced conduction disturbances requiring PPM replacement after TAVR in this cohort. A simple ECG analysis could help in detecting potentially lethal advanced conduction disturbances that could occur more than 48 h after TAVR. (C) 2018 by the American College of Cardiology Foundation.

Mangieri, A., Lanzillo, G., Bertoldi, L., Jabbour, R.j., Regazzoli, D., Ancona, M.b., et al. (2018). Predictors of Advanced Conduction Disturbances Requiring a Late (>= 48 H) Permanent Pacemaker Following Transcatheter Aortic Valve Replacement. JACC: CARDIOVASCULAR INTERVENTIONS, 11(15), 1519-1526 [10.1016/j.jcin.2018.06.014].

Predictors of Advanced Conduction Disturbances Requiring a Late (>= 48 H) Permanent Pacemaker Following Transcatheter Aortic Valve Replacement

Monaco F;
2018

Abstract

OBJECTIVES This study sought to determine predictors of advanced conduction disturbances requiring late (>= 48 h) permanent pacemaker replacement (PPM) after transcatheter aortic valve replacement (TAVR). METHODS Data of consecutive patients were identified by retrospective review of a TAVR database of a single center in Milan, Italy, between October 2007 and July 2015. We defined delta PR (Delta PR) and delta QRS (Delta QRS) interval as the difference between the last PR and QRS length available 48 h after TAVR and the baseline PR and QRS length. RESULTS Overall population included 740 patients. We excluded 78 patients who already had a PPM and 51 patients who received a PPM < 48 h after TAVR. The final analysis included 611 patients. Fifty-four patients (8.8%) developed an advanced conduction disturbance requiring PPM >= 48 h following TAVR. Patients who required a late PPM implant had a wider QRS width (113 +/- 25 ms vs. 105 +/- 23 ms; p = 0.009) and a higher prevalence of baseline right bundle branch block (12.9% vs. 5.3%; p = 0.026) and were more likely to have a self-expandable valve implanted (51.8% vs. 31.9%; p = 0.003). The Delta PR was 40 +/- 51 ms (p = 0.0001) and the Delta QRS was 22 +/- 61 ms (p = 0.001). Multivariable analysis revealed that baseline right bundle branch block (odds ratio: 3.56; 95% confidence interval: 1.07 to 11.77; p = 0.037) and Delta PR (odds ratio for each 10-ms increase: 1.31; 95% confidence interval: 1.18 to 1.45; p = 0.0001) are independent predictors of delayed advanced conduction disturbances. CONCLUSIONS This analysis showed that baseline right bundle branch block and the amount of increase of PR length after TAVR are independent predictors of late (>= 48 h) advanced conduction disturbances requiring PPM replacement after TAVR in this cohort. A simple ECG analysis could help in detecting potentially lethal advanced conduction disturbances that could occur more than 48 h after TAVR. (C) 2018 by the American College of Cardiology Foundation.
2018
Mangieri, A., Lanzillo, G., Bertoldi, L., Jabbour, R.j., Regazzoli, D., Ancona, M.b., et al. (2018). Predictors of Advanced Conduction Disturbances Requiring a Late (>= 48 H) Permanent Pacemaker Following Transcatheter Aortic Valve Replacement. JACC: CARDIOVASCULAR INTERVENTIONS, 11(15), 1519-1526 [10.1016/j.jcin.2018.06.014].
Mangieri, A; Lanzillo, G; Bertoldi, L; Jabbour, Rj; Regazzoli, D; Ancona, Mb; Tanaka, A; Mitomo, S; Garducci, S; Montalto, C; Pagnesi, M; Giannini, F;...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1037233
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 90
  • OpenAlex ND
social impact