OBJECTIVES: The EuroSCORE II is widely used to predict 30-day mortality in patients undergoing open and transcatheter cardiac surgery. The aim of this study is to evaluate the discriminatory ability of the EuroSCORE II in predicting 30-day mortality in a large cohort of patients undergoing surgical mitral valve repair in a high-volume centre. METHODS: A retrospective review of our institutional database was carried on to find all patients who underwent mitral valve repair in our department from January 2012 to December 2019. Discrimination of the EuroSCORE II was assessed using receiver operating characteristic curves. The maximum Youden's Index was employed to define the optimal cut-point. Calibration was assessed by generating calibration plot that visually compares the predicted mortality with the observed mortality. Calibration was also tested with the Hosmer-Lemeshow goodness-of-fit test. Finally, the accuracy of the models was tested calculating the Brier score. RESULTS: A total of 2645 patients were identified, and the median EuroSCORE II was 1.3% (0.6-2.0%). In patients with degenerative mitral regurgitation (MR), the EuroSCORE II showed low discrimination (area under the curve 0.68), low accuracy (Brier score 0.27) and low calibration with overestimation of the 30-day mortality. In patients with secondary MR, the EuroSCORE II showed a good overall performance estimating the 30-day mortality with good discrimination (area under the curve 0.88), good accuracy (Brier score 0.003) and good calibration. CONCLUSIONS: In patients with degenerative MR operated on in a high-volume centre with a high level of expertise in mitral valve repair, the EuroSCORE II significantly overestimates the 30-day mortality. © 2020 The Author(s). Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Carino, D., Denti, P., Ascione, G., Del Forno, B., Lapenna, E., Ruggeri, S., et al. (2021). Is the EuroSCORE II reliable in surgical mitral valve repair? A single-centre validation study. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 59(4), 863-868 [10.1093/ejcts/ezaa403].

Is the EuroSCORE II reliable in surgical mitral valve repair? A single-centre validation study

Monaco F.;
2021

Abstract

OBJECTIVES: The EuroSCORE II is widely used to predict 30-day mortality in patients undergoing open and transcatheter cardiac surgery. The aim of this study is to evaluate the discriminatory ability of the EuroSCORE II in predicting 30-day mortality in a large cohort of patients undergoing surgical mitral valve repair in a high-volume centre. METHODS: A retrospective review of our institutional database was carried on to find all patients who underwent mitral valve repair in our department from January 2012 to December 2019. Discrimination of the EuroSCORE II was assessed using receiver operating characteristic curves. The maximum Youden's Index was employed to define the optimal cut-point. Calibration was assessed by generating calibration plot that visually compares the predicted mortality with the observed mortality. Calibration was also tested with the Hosmer-Lemeshow goodness-of-fit test. Finally, the accuracy of the models was tested calculating the Brier score. RESULTS: A total of 2645 patients were identified, and the median EuroSCORE II was 1.3% (0.6-2.0%). In patients with degenerative mitral regurgitation (MR), the EuroSCORE II showed low discrimination (area under the curve 0.68), low accuracy (Brier score 0.27) and low calibration with overestimation of the 30-day mortality. In patients with secondary MR, the EuroSCORE II showed a good overall performance estimating the 30-day mortality with good discrimination (area under the curve 0.88), good accuracy (Brier score 0.003) and good calibration. CONCLUSIONS: In patients with degenerative MR operated on in a high-volume centre with a high level of expertise in mitral valve repair, the EuroSCORE II significantly overestimates the 30-day mortality. © 2020 The Author(s). Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
2021
Carino, D., Denti, P., Ascione, G., Del Forno, B., Lapenna, E., Ruggeri, S., et al. (2021). Is the EuroSCORE II reliable in surgical mitral valve repair? A single-centre validation study. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 59(4), 863-868 [10.1093/ejcts/ezaa403].
Carino, D.; Denti, P.; Ascione, G.; Del Forno, B.; Lapenna, E.; Ruggeri, S.; Agricola, E.; Buzzatti, N.; Verzini, A.; Meneghin, R.; Scandroglio, A. M....espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1036549
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact