Background: The new dedicated stents for endoscopic ultrasound (EUS)-guided transluminal drainage of peri‑pancreatic fluid collections (PFCs) demonstrated optimal efficacy and safety profiles. Aims: This study aimed to evaluate the safety, technical and clinical success, and recurrence rate of PFCs drained with Lumen Apposing Metal Stent (LAMS) or Bi-Flanged Metal Stent (BFMS). Methods: Data from a multicenter series of PFCs treated with LAMS or BFMS at 30 Italian centers during a 5-year period were retrieved. The rate of adverse events (AEs), technical success, clinical success, PFC recurrence were evaluated. To overcome biases, a 1-to-1 match was created using propensity score analysis. Results: Out of 476 patients, 386 were treated with LAMS and 90 with BFMS, with a median follow-up of 290 days (95% CI 244 to 361). Using propensity score matching, 84 patients were assigned to each group. The incidence of AEs did not differ between the two stents (13.1% versus 15.5%, p = 0.29), mainly bleeding or recurrence rate (4.7% versus 3.5%, p = 1). Technical and clinical success in the BFMS and LAMS groups were 92% versus 95% (p = 0.36) and 91% versus 94% (p = 0.64), respectively. Conclusion: Our study demonstrates that LAMS and BFMS have comparable safety profiles with similar technical and clinical success rates for EUS-guided PFC drainage.

Coluccio, C., Facciorusso, A., Forti, E., De Nucci, G., Mitri, R.D., Togliani, T., et al. (2024). Endoscopic ultrasound-guided drainage of pancreatic collections with dedicated metal stents: A nationwide, multicenter, propensity score-matched comparison. DIGESTIVE AND LIVER DISEASE, 56(1), 159-169 [10.1016/j.dld.2023.07.012].

Endoscopic ultrasound-guided drainage of pancreatic collections with dedicated metal stents: A nationwide, multicenter, propensity score-matched comparison

Facciorusso A.;Fabbri C.;Crinò S. F.;Binda C.;Attili F.;Fusaroli P.;Lisotti A.;Mutignani M.;
2024

Abstract

Background: The new dedicated stents for endoscopic ultrasound (EUS)-guided transluminal drainage of peri‑pancreatic fluid collections (PFCs) demonstrated optimal efficacy and safety profiles. Aims: This study aimed to evaluate the safety, technical and clinical success, and recurrence rate of PFCs drained with Lumen Apposing Metal Stent (LAMS) or Bi-Flanged Metal Stent (BFMS). Methods: Data from a multicenter series of PFCs treated with LAMS or BFMS at 30 Italian centers during a 5-year period were retrieved. The rate of adverse events (AEs), technical success, clinical success, PFC recurrence were evaluated. To overcome biases, a 1-to-1 match was created using propensity score analysis. Results: Out of 476 patients, 386 were treated with LAMS and 90 with BFMS, with a median follow-up of 290 days (95% CI 244 to 361). Using propensity score matching, 84 patients were assigned to each group. The incidence of AEs did not differ between the two stents (13.1% versus 15.5%, p = 0.29), mainly bleeding or recurrence rate (4.7% versus 3.5%, p = 1). Technical and clinical success in the BFMS and LAMS groups were 92% versus 95% (p = 0.36) and 91% versus 94% (p = 0.64), respectively. Conclusion: Our study demonstrates that LAMS and BFMS have comparable safety profiles with similar technical and clinical success rates for EUS-guided PFC drainage.
2024
Coluccio, C., Facciorusso, A., Forti, E., De Nucci, G., Mitri, R.D., Togliani, T., et al. (2024). Endoscopic ultrasound-guided drainage of pancreatic collections with dedicated metal stents: A nationwide, multicenter, propensity score-matched comparison. DIGESTIVE AND LIVER DISEASE, 56(1), 159-169 [10.1016/j.dld.2023.07.012].
Coluccio, C.; Facciorusso, A.; Forti, E.; De Nucci, G.; Mitri, R. D.; Togliani, T.; Cugia, L.; Ofosu, A.; Anderloni, A.; Tarantino, I.; Fabbri, C.; Cr...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1033584
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact