Since year 2009, the joint of the toroidal field (TF) conductor samples tested in the SULTAN facility at PSI Villigen, CH, is solder-filled, so that the helium coolant can only flow axially inside the central channel. The latter is however plugged starting about 40–45 mm downstream of the joint. The helium has then to pass from the central channel into the annular cable region over such a short length that the desired homogeneity of the flow distribution among the petals in the high field region is not guaranteed a priori, since central helix and petal wrappings act as azimuthally non-uniform obstacles to the radial flow. In the paper we first present a geometrical model for estimating this interference to the radial flow, and combine it with a CFD (ANSYS-FLUENT) model of the hydraulic effect of the plug, in order to estimate the mass flow rate imbalance among the petals at the beginning of the plug. This is then used as boundary condition by the THELMA code, to parametrically assess the results of a TCS measurement.

Effects of Mass Flow Rate Imbalance Among Petals During Tcs Measurements of ITER TF Short Samples in Sultan / L. Savoldi Richard; F. Bellina; M. Breschi; P. L. Ribani; F. Subba; R. Zanino. - In: IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY. - ISSN 1051-8223. - STAMPA. - 21:(2011), pp. 1978-1981. [10.1109/TASC.2010.2087732]

Effects of Mass Flow Rate Imbalance Among Petals During Tcs Measurements of ITER TF Short Samples in Sultan

BRESCHI, MARCO;RIBANI, PIER LUIGI;
2011

Abstract

Since year 2009, the joint of the toroidal field (TF) conductor samples tested in the SULTAN facility at PSI Villigen, CH, is solder-filled, so that the helium coolant can only flow axially inside the central channel. The latter is however plugged starting about 40–45 mm downstream of the joint. The helium has then to pass from the central channel into the annular cable region over such a short length that the desired homogeneity of the flow distribution among the petals in the high field region is not guaranteed a priori, since central helix and petal wrappings act as azimuthally non-uniform obstacles to the radial flow. In the paper we first present a geometrical model for estimating this interference to the radial flow, and combine it with a CFD (ANSYS-FLUENT) model of the hydraulic effect of the plug, in order to estimate the mass flow rate imbalance among the petals at the beginning of the plug. This is then used as boundary condition by the THELMA code, to parametrically assess the results of a TCS measurement.
2011
Effects of Mass Flow Rate Imbalance Among Petals During Tcs Measurements of ITER TF Short Samples in Sultan / L. Savoldi Richard; F. Bellina; M. Breschi; P. L. Ribani; F. Subba; R. Zanino. - In: IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY. - ISSN 1051-8223. - STAMPA. - 21:(2011), pp. 1978-1981. [10.1109/TASC.2010.2087732]
L. Savoldi Richard; F. Bellina; M. Breschi; P. L. Ribani; F. Subba; R. Zanino
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/103073
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact