The Near-Infrared Spectrometer and Photometer (NISP) on board the Euclid satellite provides multiband photometry and R ≳ 450 slitless grism spectroscopy in the 950- 2020 nm wavelength range. In this reference article, we illuminate the background of NISP' s functional and calibration requirements, describe the instrument' s integral components, and provide all its key properties. We also sketch the processes needed to understand how NISP operates and is calibrated as well as its technical potentials and limitations. Links to articles providing more details and the technical background are included. The NISP' s 16 HAWAII-2RG (H2RG) detectors with a plate scale of 03.3 pixel-1 deliver a field of view of 0.57 deg2. In photometric mode, NISP reaches a limiting magnitude of ~24.5 AB mag in three photometric exposures of about 100 s in exposure time for point sources and with a S/N of five. For spectroscopy, NISP' s pointsource sensitivity is a signal-to-noise ratio = 3.5 detection of an emission line with flux 2 10-16 erg s-1 cm-2 integrated over two resolution elements of 13.4 in 3-560 s grism exposures at 1.6 μm (redshifted Hα). Our calibration includes on-ground and in-flight characterisation and monitoring of the pixel-based detector baseline, dark current, non-linearity, and sensitivity to guarantee a relative photometric accuracy better than 1.5% and a relative spectrophotometry better than 0.7%. The wavelength calibration must be accurate to 5 or better. The NISP is the state-of-the-art instrument in the near-infrared for all science beyond small areas available from HST and JWST - and it represents an enormous advance from any existing instrumentation due to its combination of field size and high throughput of telescope and instrument. During Euclid' s six-year survey covering 14 000 deg2 of extragalactic sky, NISP will be the backbone in determining distances of more than a billion galaxies. Its near-infrared data will become a rich reference imaging and spectroscopy data set for the coming decades.
Jahnke, K., Gillard, W., Schirmer, M., Ealet, A., Maciaszek, T., Prieto, E., et al. (2025). Euclid. III. The NISP Instrument. ASTRONOMY & ASTROPHYSICS, 697, 1-31 [10.1051/0004-6361/202450786].
Euclid. III. The NISP Instrument
K. Jahnke;W. Gillard;M. Schirmer;A. Ealet;T. Maciaszek;E. Prieto;R. Barbier;C. Bonoli;L. Corcione;S. Dusini;F. Grupp;F. Hormuth;S. Ligori;L. Martin;G. Morgante;C. Padilla;R. Toledo-Moreo;M. Trifoglio;L. Valenziano;R. Bender;F. J. Castander;B. Garilli;P. B. Lilje;H. -W. Rix;M. I. Andersen;N. Auricchio;A. Balestra;J. -C. Barriere;P. Battaglia;M. Berthe;C. Bodendorf;T. Boenke;W. Bon;A. Bonnefoi;A. Caillat;V. Capobianco;M. Carle;R. Casas;H. Cho;A. Costille;F. Ducret;S. Ferriol;E. Franceschi;J. -L. Gimenez;W. Holmes;A. Hornstrup;M. Jhabvala;R. Kohley;B. Kubik;R. Laureijs;D. Le Mignant;I. Lloro;E. Medinaceli;Y. Mellier;G. Polenta;G. D. Racca;A. Renzi;J. -C. Salvignol;A. Secroun;G. Seidel;M. Seiffert;C. Sirignano;G. Sirri;P. Strada;G. Smadja;L. Stanco;S. Wachter;S. Anselmi;E. Borsato;L. Caillat;F. Cogato;C. Colodro-Conde;P. -E. Crouzet;V. Conforti;M. D???Alessandro;Y. Copin;J. -C. Cuillandre;J. E. Davies;S. Davini;A. Derosa;J. J. Diaz;S. Di Domizio;D. Di Ferdinando;R. Farinelli;A. G. Ferrari;F. Fornari;L. Gabarra;R. Garcia;C. M. Gutierrez;F. Giacomini;P. Lagier;F. Gianotti;O. Krause;F. Madrid;F. Laudisio;J. Macias-Perez;G. Naletto;M. Niclas;J. Marpaud;N. Mauri;R. da Silva;F. Passalacqua;K. Paterson;L. Patrizii;I. Risso;B. G. B. Solheim;M. Scodeggio;P. Stassi;J. Steinwagner;M. Tenti;G. Testera;R. Travaglini;S. Tosi;A. Troja;O. Tubio;C. Valieri;C. Vescovi;S. Ventura;N. Aghanim;B. Altieri;A. Amara;J. Amiaux;S. Andreon;P. N. Appleton;H. Aussel;C. Baccigalupi;M. Baldi;S. Bardelli;A. Basset;A. Bonchi;D. Bonino;E. Branchini;M. Brescia;J. Brinchmann;S. Camera;C. Carbone;V. F. Cardone;J. Carretero;S. Casas;M. Castellano;G. Castignani;S. Cavuoti;P. -Y. Chabaud;A. Cimatti;G. Congedo;C. J. Conselice;L. Conversi;F. Courbin;H. M. Courtois;M. Crocce;M. Cropper;J. -G. Cuby;A. Da Silva;H. Degaudenzi;G. De Lucia;A. M. Di Giorgio;J. Dinis;M. Douspis;F. Dubath;C. A. J. Duncan;X. Dupac;M. Fabricius;M. Farina;S. Farrens;F. Faustini;P. Fosalba;S. Fotopoulou;N. Fourmanoit;M. Frailis;P. Franzetti;S. Galeotta;K. George;B. Gillis;C. Giocoli;P. G??mez-Alvarez;B. R. Granett;A. Grazian;L. Guzzo;M. Hailey;S. V. H. Haugan;J. Hoar;H. Hoekstra;I. Hook;P. Hudelot;S. Ili??;B. Joachimi;E. Keih??nen;S. Kermiche;A. Kiessling;M. Kilbinger;T. Kitching;M. K??mmel;M. Kunz;H. Kurki-Suonio;O. Lahav;P. Liebing;V. Lindholm;J. Lorenzo Alvarez;G. Mainetti;D. Maino;E. Maiorano;O. Mansutti;S. Marcin;O. Marggraf;K. Markovic;J. Martignac;M. Martinelli;N. Martinet;F. Marulli;R. Massey;D. C. Masters;S. Maurogordato;H. J. McCracken;S. Mei;M. Melchior;M. Meneghetti;E. Merlin;G. Meylan;J. J. Mohr;M. Moresco;P. W. Morris;L. Moscardini;R. Nakajima;C. Neissner;R. C. Nichol;S. -M. Niemi;T. Nutma;K. Paech;S. Paltani;F. Pasian;J. A. Peacock;K. Pedersen;W. J. Percival;V. Pettorino;S. Pires;M. Poncet;L. A. Popa;L. Pozzetti;F. Raison;R. Rebolo;A. Refregier;J. Rhodes;G. Riccio;E. Romelli;M. Roncarelli;C. Rosset;E. Rossetti;H. J. A. Rottgering;B. Rusholme;R. Saglia;Z. Sakr;A. G. S??nchez;D. Sapone;M. Sauvage;R. Scaramella;J. A. Schewtschenko;P. Schneider;T. Schrabback;E. Sefusatti;S. Serrano;P. Tallada-Cresp??;D. Tavagnacco;A. N. Taylor;H. I. Teplitz;I. Tereno;F. Torradeflot;I. Tutusaus;T. Vassallo;G. Verdoes Kleijn;A. Veropalumbo;D. Vibert;Y. Wang;J. Weller;A. Zacchei;G. Zamorani;F. M. Zerbi;J. Zoubian;E. Zucca;A. Biviano;M. Bolzonella;A. Boucaud;E. Bozzo;C. Burigana;M. Calabrese;P. Casenove;J. A. Escartin Vigo;G. Fabbian;F. Finelli;J. Gracia-Carpio;C. Liu;A. Pezzotta;M. P??ntinen;C. Porciani;V. Scottez;M. Viel;M. Wiesmann;Y. Akrami;V. Allevato;E. Aubourg;M. Ballardini;D. Bertacca;M. Bethermin;A. Blanchard;L. Blot;S. Borgani;A. S. Borlaff;S. Bruton;R. Cabanac;A. Calabro;G. Calderone;G. Canas-Herrera;A. Cappi;C. S. Carvalho;T. Castro;K. C. Chambers;Y. Charles;R. Chary;J. Colbert;S. Contarini;T. Contini;A. R. Cooray;M. Costanzi;O. Cucciati;B. De Caro;S. de la Torre;G. Desprez;A. D??az-S??nchez;H. Dole;S. Escoffier;P. G. Ferreira;I. Ferrero;A. Finoguenov;A. Fontana;K. Ganga;J. Garc??a-Bellido;V. Gautard;E. Gaztanaga;G. Gozaliasl;A. Gregorio;A. Hall;W. G. Hartley;S. Hemmati;H. Hildebrandt;J. Hjorth;S. Hosseini;M. Huertas-Company;O. Ilbert;J. Jacobson;A. Jimenez Mu??oz;S. Joudaki;J. J. E. Kajava;V. Kansal;D. Karagiannis;C. C. Kirkpatrick;F. Lacasa;V. Le Brun;J. Le Graet;L. Legrand;G. Libet;S. J. Liu;A. Loureiro;M. Magliocchetti;C. Mancini;F. Mannucci;R. Maoli;C. J. A. P. Martins;S. Matthew;L. Maurin;C. J. R. McPartland;R. B. Metcalf;M. Migliaccio;M. Miluzio;P. Monaco;C. Moretti;S. Nadathur;L. Nicastro;Nicholas A. Walton;J. Odier;M. Oguri;V. Popa;D. Potter;A. Pourtsidou;P. -F. Rocci;R. P. Rollins;M. Sahl??n;C. Scarlata;J. Schaye;A. Schneider;M. Schultheis;M. Sereno;F. Shankar;A. Shulevski;G. Sikkema;A. Silvestri;P. Simon;A. Spurio Mancini;J. Stadel;S. A. Stanford;K. Tanidis;C. Tao;N. Tessore;R. Teyssier;S. Toft;M. Tucci;J. Valiviita;D. Vergani;F. Vernizzi;G. Verza;P. Vielzeuf;J. R. Weaver;L. Zalesky;I. A. Zinchenko;M. Archidiacono;F. Atrio-Barandela;C. L. Bennett;T. Bouvard;F. Caro;S. Conseil;P. Dimauro;P. -A. Duc;Y. Fang;A. M. N. Ferguson;T. Gasparetto;I. Kova??i??;S. Kruk;A. M. C. Le Brun;T. I. Liaudat;A. Montoro;A. Mora;C. Murray;L. Pagano;D. Paoletti;M. Radovich;E. Sarpa;E. Tommasi;A. Viitanen;J. Lesgourgues;M. E. Levi;J. Mart??n-Fleitas;F. Oppizzi
2025
Abstract
The Near-Infrared Spectrometer and Photometer (NISP) on board the Euclid satellite provides multiband photometry and R ≳ 450 slitless grism spectroscopy in the 950- 2020 nm wavelength range. In this reference article, we illuminate the background of NISP' s functional and calibration requirements, describe the instrument' s integral components, and provide all its key properties. We also sketch the processes needed to understand how NISP operates and is calibrated as well as its technical potentials and limitations. Links to articles providing more details and the technical background are included. The NISP' s 16 HAWAII-2RG (H2RG) detectors with a plate scale of 03.3 pixel-1 deliver a field of view of 0.57 deg2. In photometric mode, NISP reaches a limiting magnitude of ~24.5 AB mag in three photometric exposures of about 100 s in exposure time for point sources and with a S/N of five. For spectroscopy, NISP' s pointsource sensitivity is a signal-to-noise ratio = 3.5 detection of an emission line with flux 2 10-16 erg s-1 cm-2 integrated over two resolution elements of 13.4 in 3-560 s grism exposures at 1.6 μm (redshifted Hα). Our calibration includes on-ground and in-flight characterisation and monitoring of the pixel-based detector baseline, dark current, non-linearity, and sensitivity to guarantee a relative photometric accuracy better than 1.5% and a relative spectrophotometry better than 0.7%. The wavelength calibration must be accurate to 5 or better. The NISP is the state-of-the-art instrument in the near-infrared for all science beyond small areas available from HST and JWST - and it represents an enormous advance from any existing instrumentation due to its combination of field size and high throughput of telescope and instrument. During Euclid' s six-year survey covering 14 000 deg2 of extragalactic sky, NISP will be the backbone in determining distances of more than a billion galaxies. Its near-infrared data will become a rich reference imaging and spectroscopy data set for the coming decades.
Jahnke, K., Gillard, W., Schirmer, M., Ealet, A., Maciaszek, T., Prieto, E., et al. (2025). Euclid. III. The NISP Instrument. ASTRONOMY & ASTROPHYSICS, 697, 1-31 [10.1051/0004-6361/202450786].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1016897
Citazioni
ND
2
3
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.