A novel approach to the diagnosis of bone available for craniofacial implant positioning is discussed in a case that required ear ablation for tumor removal. A mirrored volume of the healthy ear was rapidly prototyped for a clinical trial in an appropriate position relative to the patient's face. Three ideal positions for the implant were chosen in the inner of the volume of the mirrored ear. The same positions were transferred to a diagnostic template that was rapidly prototyped with a positioning arm extending to the zygomatic arch. Computed tomography (CT) revealed errors in the planning of the implant position and, as a clinical consequence, an implant site was excluded from surgical planning. A virtual elaboration for maxillofacial implant positioning was used to define the correct implant site in relation to the available bone, and two craniofacial implants were correctly positioned in the temporal bone

L. Ciocca, R. Mingucci, G.Bacci, R. Scotti (2009). CAD-CAM construction of an auricular template for craniofacial implant positioning: a novel approach to diagnosis. EUROPEAN JOURNAL OF RADIOLOGY, 71(2), 253-256 [10.1016/j.ejrad.2008.05.004].

CAD-CAM construction of an auricular template for craniofacial implant positioning: a novel approach to diagnosis.

CIOCCA, LEONARDO;MINGUCCI, ROBERTO;BACCI, GIOVANNI;SCOTTI, ROBERTO
2009

Abstract

A novel approach to the diagnosis of bone available for craniofacial implant positioning is discussed in a case that required ear ablation for tumor removal. A mirrored volume of the healthy ear was rapidly prototyped for a clinical trial in an appropriate position relative to the patient's face. Three ideal positions for the implant were chosen in the inner of the volume of the mirrored ear. The same positions were transferred to a diagnostic template that was rapidly prototyped with a positioning arm extending to the zygomatic arch. Computed tomography (CT) revealed errors in the planning of the implant position and, as a clinical consequence, an implant site was excluded from surgical planning. A virtual elaboration for maxillofacial implant positioning was used to define the correct implant site in relation to the available bone, and two craniofacial implants were correctly positioned in the temporal bone
2009
L. Ciocca, R. Mingucci, G.Bacci, R. Scotti (2009). CAD-CAM construction of an auricular template for craniofacial implant positioning: a novel approach to diagnosis. EUROPEAN JOURNAL OF RADIOLOGY, 71(2), 253-256 [10.1016/j.ejrad.2008.05.004].
L. Ciocca; R. Mingucci; G.Bacci; R. Scotti
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/101306
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 18
social impact