Aim Prosthetic joint infection (PJI) is a common complication following orthopedic megaprosthetic implantations (EPR), estimated up to 50%. Silver coatings were introduced in order to reduce the incidence of PJI, by using the antibacterial activity of silver. Three diferent silver coatings are available: MUTARS® (Implantcast), Agluna® (Accentus Medical), PorAg® (Waldemar Link). The aim of this review is to provide an overview on efcacy and safety of silver-coated EPR both in primary and revision surgery, comparing infection rate according to the type of implant. Methods Through an electronic systematic search, we reviewed the articles concerning silver-coated EPRs. Infection rate, silver-related complications, local and blood concentrations of the silver were evaluated. Meta-analyses were performed to compare results from each study included. Results Nineteen studies were included. The overall infection rate in patients with silver-coated implants was 17.6% (133/755). Overall infection rate in primary silver-coated EPR was been 9.2% (44/445), compared to 11.2% (57/507) of non-silver-coated implants. The overall infection rate after revisions was 13.7% (25/183) in patients with silver-coated EPR and 29.2% (47/161) when uncoated EPR were used, revealing a strength statistically signifcative utility of silver coatings in preventing infections in this group (p: 0.019). Generally, the use of MUTARS® EPR had produced an almost constant decrease in the incidence of primary PJI but there are few data on the efectiveness in revisions. The results from the use of Agluna® in both primary and revisions implants are inconstant. Conversely, PorAg® had proven to be efective both in PJI prevention but, especially, when used in PJI revision settings. Local argyria was reported in 8 out of 357 patients (2.2%), while no systemic complications were described. Local and blood concentrations of silver were always reported very far to the threshold of toxicity, with the lowest concentration found using PorAg®. Conclusions Silver-coated EPRs are safe and efective in reduction in PJI and re-infection rate, in particular when used in higher risk patients and after two-stage revisions to fght PJI.

Fiore, M., Sambri, A., Zucchini, R., Giannini, C., Donati, D.M., De Paolis, M. (2020). Silver-coated megaprosthesis in prevention and treatment of peri-prosthetic infections: a systematic review and meta-analysis about efficacy and toxicity in primary and revision surgery. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY, 31(2), 201-220 [10.1007/s00590-020-02779-z].

Silver-coated megaprosthesis in prevention and treatment of peri-prosthetic infections: a systematic review and meta-analysis about efficacy and toxicity in primary and revision surgery

Sambri, Andrea;Zucchini, Riccardo;Giannini, Claudio;Donati, Davide Maria;
2020

Abstract

Aim Prosthetic joint infection (PJI) is a common complication following orthopedic megaprosthetic implantations (EPR), estimated up to 50%. Silver coatings were introduced in order to reduce the incidence of PJI, by using the antibacterial activity of silver. Three diferent silver coatings are available: MUTARS® (Implantcast), Agluna® (Accentus Medical), PorAg® (Waldemar Link). The aim of this review is to provide an overview on efcacy and safety of silver-coated EPR both in primary and revision surgery, comparing infection rate according to the type of implant. Methods Through an electronic systematic search, we reviewed the articles concerning silver-coated EPRs. Infection rate, silver-related complications, local and blood concentrations of the silver were evaluated. Meta-analyses were performed to compare results from each study included. Results Nineteen studies were included. The overall infection rate in patients with silver-coated implants was 17.6% (133/755). Overall infection rate in primary silver-coated EPR was been 9.2% (44/445), compared to 11.2% (57/507) of non-silver-coated implants. The overall infection rate after revisions was 13.7% (25/183) in patients with silver-coated EPR and 29.2% (47/161) when uncoated EPR were used, revealing a strength statistically signifcative utility of silver coatings in preventing infections in this group (p: 0.019). Generally, the use of MUTARS® EPR had produced an almost constant decrease in the incidence of primary PJI but there are few data on the efectiveness in revisions. The results from the use of Agluna® in both primary and revisions implants are inconstant. Conversely, PorAg® had proven to be efective both in PJI prevention but, especially, when used in PJI revision settings. Local argyria was reported in 8 out of 357 patients (2.2%), while no systemic complications were described. Local and blood concentrations of silver were always reported very far to the threshold of toxicity, with the lowest concentration found using PorAg®. Conclusions Silver-coated EPRs are safe and efective in reduction in PJI and re-infection rate, in particular when used in higher risk patients and after two-stage revisions to fght PJI.
2020
Fiore, M., Sambri, A., Zucchini, R., Giannini, C., Donati, D.M., De Paolis, M. (2020). Silver-coated megaprosthesis in prevention and treatment of peri-prosthetic infections: a systematic review and meta-analysis about efficacy and toxicity in primary and revision surgery. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY, 31(2), 201-220 [10.1007/s00590-020-02779-z].
Fiore, Michele; Sambri, Andrea; Zucchini, Riccardo; Giannini, Claudio; Donati, Davide Maria; De Paolis, Massimiliano
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1012679
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 74
  • ???jsp.display-item.citation.isi??? 66
social impact