Background Cannulation strategy in acute type A dissection (ATAD) varies widely without known gold standards. This study compared ATAD outcomes of axillary vs femoral artery cannulation in a large cohort from the International Registry of Acute Aortic Dissection (IRAD). Methods The study retrospectively reviewed 2145 patients from the IRAD Interventional Cohort (1996-2021) who underwent ATAD repair with axillary or femoral cannulation (axillary group: n = 1106 [52%]; femoral group: n = 1039 [48%]). End points included the following: early mortality; neurologic, respiratory, and renal complications; malperfusion; and tamponade. All outcomes are presented as axillary with respect to femoral. Results The proportion of patients younger than 70 years in both groups was similar (n = 1577 [74%]), as were bicuspid aortic valve, Marfan syndrome, and previous dissection. Patients with femoral cannulation had slightly more aortic insufficiency (408 [55%] vs 429 [60%]; P = .058) and coronary involvement (48 [8%] vs 70 [13%]; P = .022]. Patients with axillary cannulation underwent more total aortic arch (156 [15%] vs 106 [11%]; P = .02) and valve-sparing root replacements (220 [22%] vs 112 [12%]; P < .001). More patients with femoral cannulation underwent commissural resuspension (269 [30.9%] vs 324 [35.3%]; P = .05). Valve replacement rates were not different. The mean duration of cardiopulmonary bypass was longer in the femoral group (190 [149-237] minutes vs 196 [159-247] minutes; P = .037). In-hospital mortality was similar between the axillary (n = 165 [15%]) and femoral (n = 149 [14%]) groups (P = .7). Furthermore, there were no differences in stroke, visceral ischemia, tamponade, respiratory insufficiency, coma, or spinal cord ischemia. Conclusions Axillary cannulation is associated with a more stable ATAD presentation, but it is a more extensive intervention compared with femoral cannulation. Both procedures have equivalent early mortality, stroke, tamponade, and malperfusion outcomes after statistical adjustment.

Elbatarny, M., Trimarchi, S., Korach, A., Di Eusanio, M., Pacini, D., Bekeredjian, R., et al. (2024). Axillary vs Femoral Arterial Cannulation in Acute Type A Dissection: International Multicenter Data. ANNALS OF THORACIC SURGERY, 117(6), 1128-1134 [10.1016/j.athoracsur.2024.02.026].

Axillary vs Femoral Arterial Cannulation in Acute Type A Dissection: International Multicenter Data

Di Eusanio M.;Pacini D.;
2024

Abstract

Background Cannulation strategy in acute type A dissection (ATAD) varies widely without known gold standards. This study compared ATAD outcomes of axillary vs femoral artery cannulation in a large cohort from the International Registry of Acute Aortic Dissection (IRAD). Methods The study retrospectively reviewed 2145 patients from the IRAD Interventional Cohort (1996-2021) who underwent ATAD repair with axillary or femoral cannulation (axillary group: n = 1106 [52%]; femoral group: n = 1039 [48%]). End points included the following: early mortality; neurologic, respiratory, and renal complications; malperfusion; and tamponade. All outcomes are presented as axillary with respect to femoral. Results The proportion of patients younger than 70 years in both groups was similar (n = 1577 [74%]), as were bicuspid aortic valve, Marfan syndrome, and previous dissection. Patients with femoral cannulation had slightly more aortic insufficiency (408 [55%] vs 429 [60%]; P = .058) and coronary involvement (48 [8%] vs 70 [13%]; P = .022]. Patients with axillary cannulation underwent more total aortic arch (156 [15%] vs 106 [11%]; P = .02) and valve-sparing root replacements (220 [22%] vs 112 [12%]; P < .001). More patients with femoral cannulation underwent commissural resuspension (269 [30.9%] vs 324 [35.3%]; P = .05). Valve replacement rates were not different. The mean duration of cardiopulmonary bypass was longer in the femoral group (190 [149-237] minutes vs 196 [159-247] minutes; P = .037). In-hospital mortality was similar between the axillary (n = 165 [15%]) and femoral (n = 149 [14%]) groups (P = .7). Furthermore, there were no differences in stroke, visceral ischemia, tamponade, respiratory insufficiency, coma, or spinal cord ischemia. Conclusions Axillary cannulation is associated with a more stable ATAD presentation, but it is a more extensive intervention compared with femoral cannulation. Both procedures have equivalent early mortality, stroke, tamponade, and malperfusion outcomes after statistical adjustment.
2024
Elbatarny, M., Trimarchi, S., Korach, A., Di Eusanio, M., Pacini, D., Bekeredjian, R., et al. (2024). Axillary vs Femoral Arterial Cannulation in Acute Type A Dissection: International Multicenter Data. ANNALS OF THORACIC SURGERY, 117(6), 1128-1134 [10.1016/j.athoracsur.2024.02.026].
Elbatarny, M.; Trimarchi, S.; Korach, A.; Di Eusanio, M.; Pacini, D.; Bekeredjian, R.; Myrmel, T.; Bavaria, J. E.; Desai, N. D.; Sultan, I.; Brinster,...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1009121
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact