Background and objectives: The diagnosis of narcolepsy type 1 (NT1) currently requires the multiple sleep latency test (MSLT), or a nocturnal sleep-onset REM period (SOREMP) combined with typical cataplexy, or alternatively the determination of CSF hypocretin-1 (CSF-hcrt-1) deficiency. We evaluated the 24-hour polysomnography (PSG) recordings in adult and pediatric patients as an alternative diagnostic tool. Methods: Patients of any age, referred to the narcolepsy center of a university hospital for suspected central disorder of hypersomnolence (CDH), were consecutively recruited between 2013 and 2022. Participants underwent 2 days (day1-night1-day2-night2) of continuous dynamic PSG followed by MSLT. When consent was given, CSF-hcrt-1 was measured. The accuracy of 24-hour PSG variables from night1 and day2 (index test) was assessed with receiver operating characteristic (ROC) curve analysis in identifying NT1 based on current criteria (applied to night2-PSG, MSLT, and CSF-hcrt1). The markers with area under the curve (AUC) ≥0.75 were then tested in adults and children, separately, and to diagnose NT1 and narcolepsy type 2 (NT2) in different scenarios. Results: Eight hundred seven patients (30.1% pediatric, 52.4% male) were included, and 709 had CSF-hcrt-1 measured. According to the standard criteria, 322 were diagnosed with NT1 (mean age 26.7 ± 17.1 years, 40.4% pediatric, 54.0% male) and 484 with non-NT1 (mean age 32.7 ± 16.5 years, 23.3% pediatric, 51.3% male), encompassing 31 with NT2, 163 with idiopathic hypersomnia, and 281 with other diagnoses. Detecting SOREMP ≥1 during daytime resulted in AUC = 0.84 (95% CI 0.82-0.87), with 84.4% sensitivity and 84.5% specificity for NT1. Performance was superior to all nighttime-PSG measures (p < 0.001) including nighttime-SOREMP (AUC = 0.77, 95% CI 0.74-0.80; sensitivity = 62.1%, specificity = 91.7%) and did not differ from 24-hour SOREMP ≥1 (AUC = 0.85, 95% CI 0.82-0.87; sensitivity = 89.7%, specificity = 80.2%). The combination of daytime-SOREMP ≥1 with cataplexy showed AUC = 0.89 (95% CI 0.86-0.91) for NT1, superior to the combination of nighttime-SOREMP with cataplexy (AUC = 0.78, 95% CI 0.76-0.81, p < 0.001) and similar to MSLT criteria for narcolepsy (AUC = 0.90, 95% CI 0.88-0.92, p = 0.36). Performances were similar in adults and children. Daytime-SOREMP ≥1 identified NT1 and NT2 combined within all CDH with a sensitivity of 80.8% and specificity of 88.0%. Conclusions: The detection of daytime-SOREMP during dynamic 24-hour PSG is more accurate than nighttime-SOREMP for diagnosing narcolepsy and, combined with cataplexy, is comparable with MSLT criteria for the identification of NT1. These results offer the prospect of 24-hour PSG diagnostics for NT1 in the home setting. Classification of evidence: This study provides Class II evidence that daytime SOREMP during a 24-hour PSG accurately distinguishes NT1 in patients with a clinical history of possible cataplexy from those who do not have NT1.

Biscarini, F., Vandi, S., Zenesini, C., Vignatelli, L., Citeroni, F., Antelmi, E., et al. (2025). Use of Portable 24-Hour Polysomnography as Alternative Diagnostic Tool for Narcolepsy Type 1 in Adults and Children. NEUROLOGY, 104(7), e213473-e213473 [10.1212/WNL.0000000000213473].

Use of Portable 24-Hour Polysomnography as Alternative Diagnostic Tool for Narcolepsy Type 1 in Adults and Children

Biscarini, Francesco;Vandi, Stefano;Pizza, Fabio
2025

Abstract

Background and objectives: The diagnosis of narcolepsy type 1 (NT1) currently requires the multiple sleep latency test (MSLT), or a nocturnal sleep-onset REM period (SOREMP) combined with typical cataplexy, or alternatively the determination of CSF hypocretin-1 (CSF-hcrt-1) deficiency. We evaluated the 24-hour polysomnography (PSG) recordings in adult and pediatric patients as an alternative diagnostic tool. Methods: Patients of any age, referred to the narcolepsy center of a university hospital for suspected central disorder of hypersomnolence (CDH), were consecutively recruited between 2013 and 2022. Participants underwent 2 days (day1-night1-day2-night2) of continuous dynamic PSG followed by MSLT. When consent was given, CSF-hcrt-1 was measured. The accuracy of 24-hour PSG variables from night1 and day2 (index test) was assessed with receiver operating characteristic (ROC) curve analysis in identifying NT1 based on current criteria (applied to night2-PSG, MSLT, and CSF-hcrt1). The markers with area under the curve (AUC) ≥0.75 were then tested in adults and children, separately, and to diagnose NT1 and narcolepsy type 2 (NT2) in different scenarios. Results: Eight hundred seven patients (30.1% pediatric, 52.4% male) were included, and 709 had CSF-hcrt-1 measured. According to the standard criteria, 322 were diagnosed with NT1 (mean age 26.7 ± 17.1 years, 40.4% pediatric, 54.0% male) and 484 with non-NT1 (mean age 32.7 ± 16.5 years, 23.3% pediatric, 51.3% male), encompassing 31 with NT2, 163 with idiopathic hypersomnia, and 281 with other diagnoses. Detecting SOREMP ≥1 during daytime resulted in AUC = 0.84 (95% CI 0.82-0.87), with 84.4% sensitivity and 84.5% specificity for NT1. Performance was superior to all nighttime-PSG measures (p < 0.001) including nighttime-SOREMP (AUC = 0.77, 95% CI 0.74-0.80; sensitivity = 62.1%, specificity = 91.7%) and did not differ from 24-hour SOREMP ≥1 (AUC = 0.85, 95% CI 0.82-0.87; sensitivity = 89.7%, specificity = 80.2%). The combination of daytime-SOREMP ≥1 with cataplexy showed AUC = 0.89 (95% CI 0.86-0.91) for NT1, superior to the combination of nighttime-SOREMP with cataplexy (AUC = 0.78, 95% CI 0.76-0.81, p < 0.001) and similar to MSLT criteria for narcolepsy (AUC = 0.90, 95% CI 0.88-0.92, p = 0.36). Performances were similar in adults and children. Daytime-SOREMP ≥1 identified NT1 and NT2 combined within all CDH with a sensitivity of 80.8% and specificity of 88.0%. Conclusions: The detection of daytime-SOREMP during dynamic 24-hour PSG is more accurate than nighttime-SOREMP for diagnosing narcolepsy and, combined with cataplexy, is comparable with MSLT criteria for the identification of NT1. These results offer the prospect of 24-hour PSG diagnostics for NT1 in the home setting. Classification of evidence: This study provides Class II evidence that daytime SOREMP during a 24-hour PSG accurately distinguishes NT1 in patients with a clinical history of possible cataplexy from those who do not have NT1.
2025
Biscarini, F., Vandi, S., Zenesini, C., Vignatelli, L., Citeroni, F., Antelmi, E., et al. (2025). Use of Portable 24-Hour Polysomnography as Alternative Diagnostic Tool for Narcolepsy Type 1 in Adults and Children. NEUROLOGY, 104(7), e213473-e213473 [10.1212/WNL.0000000000213473].
Biscarini, Francesco; Vandi, Stefano; Zenesini, Corrado; Vignatelli, Luca; Citeroni, Francesca; Antelmi, Elena; Franceschini, Christian; Barateau, Luc...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1009080
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact