Background: New conduction disturbances are frequent after transcatheter aortic valve implantation (TAVI). Refining our ability to predict high-grade atrioventricular block (AVB) occurring later than 24 hours after the procedure would be useful in order to select patients eligible for early discharge. Aims: This study was designed to identify predictors of high-grade AVB occurring between 24 hours and 30 days after TAVI and to develop and validate a predictive risk score. Methods: We analysed clinical, procedural, and electrocardiographic parameters of 1,290 TAVI patients. Independent predictors of delayed high-grade AVB were used to develop the predictive score, which was then externally validated in a cohort of 936 patients. Results: Implantation of self-expanding valves, greater implantation depth, longer PR interval in preprocedural electrocardiogram (ECG) and greater increase of PR duration in next-day ECG, preprocedural right bundle branch block (RBBB) and new-onset left bundle branch block or RBBB that persisted in next-day ECG were independent predictors of delayed high-grade AVB and were combined to develop the Delayed atrioventricular block Prediction for eArly disChargE (D-PACE) score. The areas under the curve of the score were 0.879 (95% confidence interval [CI]: 0.835-0.923) and 0.799 (95% CI: 0.730-0.868) in the derivation and validation cohorts, respectively. Based on the score, patients can be classified into three risk categories; low-risk patients demonstrated an incidence of delayed AVB of less than 1% and are ideal candidates for next-day discharge. Conclusions: The D-PACE score can be used to stratify TAVI patients according to their risk of delayed high-grade AVB and thereby identify those suitable for next-day discharge.

Bendandi, F., Taglieri, N., Ciurlanti, L., Mazzapicchi, A., Foroni, M., Lombardi, L., et al. (2025). Development and validation of the D-PACE scoring system to predict delayed high-grade conduction disturbances after transcatheter aortic valve implantation. EUROINTERVENTION, 21(2), e119-e129 [10.4244/EIJ-D-24-00850].

Development and validation of the D-PACE scoring system to predict delayed high-grade conduction disturbances after transcatheter aortic valve implantation

Bendandi F.;Taglieri N.;Ciurlanti L.;Mazzapicchi A.;Foroni M.;Lombardi L.;Palermo F.;Filice F.;Ghetti G.;Bruno A. G.;Orzalkiewicz M.;Comis A.;Palmerini T.;Barbanti M.;Saia F.
2025

Abstract

Background: New conduction disturbances are frequent after transcatheter aortic valve implantation (TAVI). Refining our ability to predict high-grade atrioventricular block (AVB) occurring later than 24 hours after the procedure would be useful in order to select patients eligible for early discharge. Aims: This study was designed to identify predictors of high-grade AVB occurring between 24 hours and 30 days after TAVI and to develop and validate a predictive risk score. Methods: We analysed clinical, procedural, and electrocardiographic parameters of 1,290 TAVI patients. Independent predictors of delayed high-grade AVB were used to develop the predictive score, which was then externally validated in a cohort of 936 patients. Results: Implantation of self-expanding valves, greater implantation depth, longer PR interval in preprocedural electrocardiogram (ECG) and greater increase of PR duration in next-day ECG, preprocedural right bundle branch block (RBBB) and new-onset left bundle branch block or RBBB that persisted in next-day ECG were independent predictors of delayed high-grade AVB and were combined to develop the Delayed atrioventricular block Prediction for eArly disChargE (D-PACE) score. The areas under the curve of the score were 0.879 (95% confidence interval [CI]: 0.835-0.923) and 0.799 (95% CI: 0.730-0.868) in the derivation and validation cohorts, respectively. Based on the score, patients can be classified into three risk categories; low-risk patients demonstrated an incidence of delayed AVB of less than 1% and are ideal candidates for next-day discharge. Conclusions: The D-PACE score can be used to stratify TAVI patients according to their risk of delayed high-grade AVB and thereby identify those suitable for next-day discharge.
2025
Bendandi, F., Taglieri, N., Ciurlanti, L., Mazzapicchi, A., Foroni, M., Lombardi, L., et al. (2025). Development and validation of the D-PACE scoring system to predict delayed high-grade conduction disturbances after transcatheter aortic valve implantation. EUROINTERVENTION, 21(2), e119-e129 [10.4244/EIJ-D-24-00850].
Bendandi, F.; Taglieri, N.; Ciurlanti, L.; Mazzapicchi, A.; Foroni, M.; Lombardi, L.; Palermo, F.; Filice, F.; Ghetti, G.; Bruno, A. G.; Orzalkiewicz,...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1003413
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact