Multilayer Insulation (MLI) is frequently used in vacuum conditions for the thermal insulation of cryogenic storage tanks. The severe consequences of the degradation of such materials in engulfing fire scenarios were recently evidenced by several large-scale experimental tests. In the present study, an innovative modelling approach was developed to assess the performance of heat transfer in polyester-based MLI materials for cryogenic applications under fire conditions. A specific layer-by-layer approach was integrated with an apparent kinetic thermal degradation model based on thermogravimetric analysis results. The modeling results provided a realistic simulation of the experimental data obtained by High-Temperature Thermal Vacuum Chamber tests reproducing fire exposure conditions. The model was then applied to assess the behavior of MLI systems for liquid hydrogen tanks in realistic fire scenarios. The results show that in intense fire scenarios degradation occurs rapidly, compromising the thermal insulation performances of the system within a few minutes.

Camplese, D., Scarponi, G.E., Chianese, C., Hajhariri, A., Eberwein, R., Otremba, F., et al. (2024). Modeling the performance of multilayer insulation in cryogenic tanks undergoing external fire scenarios. PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 186, 1169-1182 [10.1016/j.psep.2024.04.061].

Modeling the performance of multilayer insulation in cryogenic tanks undergoing external fire scenarios

Camplese D.;Scarponi G. E.;Chianese C.;Cozzani V.
2024

Abstract

Multilayer Insulation (MLI) is frequently used in vacuum conditions for the thermal insulation of cryogenic storage tanks. The severe consequences of the degradation of such materials in engulfing fire scenarios were recently evidenced by several large-scale experimental tests. In the present study, an innovative modelling approach was developed to assess the performance of heat transfer in polyester-based MLI materials for cryogenic applications under fire conditions. A specific layer-by-layer approach was integrated with an apparent kinetic thermal degradation model based on thermogravimetric analysis results. The modeling results provided a realistic simulation of the experimental data obtained by High-Temperature Thermal Vacuum Chamber tests reproducing fire exposure conditions. The model was then applied to assess the behavior of MLI systems for liquid hydrogen tanks in realistic fire scenarios. The results show that in intense fire scenarios degradation occurs rapidly, compromising the thermal insulation performances of the system within a few minutes.
2024
Camplese, D., Scarponi, G.E., Chianese, C., Hajhariri, A., Eberwein, R., Otremba, F., et al. (2024). Modeling the performance of multilayer insulation in cryogenic tanks undergoing external fire scenarios. PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 186, 1169-1182 [10.1016/j.psep.2024.04.061].
Camplese, D.; Scarponi, G. E.; Chianese, C.; Hajhariri, A.; Eberwein, R.; Otremba, F.; Cozzani, V.
File in questo prodotto:
File Dimensione Formato  
2024_Modeling the performance of multilayer insulation in cryogenic tanks undergoing external fire scenarios.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 3.32 MB
Formato Adobe PDF
3.32 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1002479
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 3
social impact