The evaluation of the Available Safe Egress Time (ASET) is essential for organizing people evacuation in case of fire in industrial premises, buildings or generic enclosures. This task is usually achieved by considering several performance criteria and then calculating the time for reaching established threshold limits for each of those criteria. In the paper a sensitivity study for the ASET performance criteria is presented. To this aim the Fire Dynamic Simulator (FDS) has been adopted. A comparison between FDS results and an analytical approach for a quick estimation of the ASET in an enclosure is showed. The methodology may be usable as a decision support tool for emergency evacuation design and management. Copyright © 2012, AIDIC Servizi S.r.l.

Tosolini, E., Grimaz, S., Pecile, L.C, Salzano, E. (2012). People evacuation: Simplified evaluation of available safe egress time (aset) in enclosures. Milano : Italian Association of Chemical Engineering - AIDIC [10.3303/CET1226084].

People evacuation: Simplified evaluation of available safe egress time (aset) in enclosures

SALZANO, ERNESTO
2012

Abstract

The evaluation of the Available Safe Egress Time (ASET) is essential for organizing people evacuation in case of fire in industrial premises, buildings or generic enclosures. This task is usually achieved by considering several performance criteria and then calculating the time for reaching established threshold limits for each of those criteria. In the paper a sensitivity study for the ASET performance criteria is presented. To this aim the Fire Dynamic Simulator (FDS) has been adopted. A comparison between FDS results and an analytical approach for a quick estimation of the ASET in an enclosure is showed. The methodology may be usable as a decision support tool for emergency evacuation design and management. Copyright © 2012, AIDIC Servizi S.r.l.
2012
Chemical Engineering Transactions
501
506
Tosolini, E., Grimaz, S., Pecile, L.C, Salzano, E. (2012). People evacuation: Simplified evaluation of available safe egress time (aset) in enclosures. Milano : Italian Association of Chemical Engineering - AIDIC [10.3303/CET1226084].
Tosolini, E; Grimaz, S; Pecile, L.C; Salzano, E.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/526505
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact