In the last 10 years the percentage of dialysis patients suffering from clinical intradialytic intolerance has greatly increased. Profiled hemodialysis (PHD) is a new technical approach, alternative to standard hemodialysis (SHD) for the treatment of intradialytic symptomatic hypotension. It is based on intradialytic modulation of the dialysate sodium concentration, using a dialysate sodium concentration profile elaborated by a new mathematical kinetic model. The aim of PHD is to reduce the intradialytic blood volume decrease, thanks to a dialysate sodium profile, which allows a reduction in the plasma osmolarity decrease, thereby boosting intravascular fluid refilling. This work aims at clinically validating the PHD technique, by testing its ability, against SLID, to maintain a more stable intradialytic blood volume; this evaluation was supported by monitoring some hemodynamic parameters. Twelve dialysis patients on SHD treatment were selected because of their intradialytic symptomatic hypotension. Twelve SHD (one per patient) and 12 PHD sessions (one per patient) were performed to achieve the same sodium mass removal and body weight decrease on both PHD and SHD. During these sessions we monitored the blood volume variation % by the crit-line (a non invasive blood volume monitoring device), the mean blood pressure and heart rate directly and, finally, the stroke volume and cardiac output indirectly by bidimensional doppler-echocardiography comparison of the results obtained with the two techniques shows PHD to achieve a significantly more stable blood volume, blood pressure and cardiovascular function than SHD, in particular during the second and the third hour of the dialysis session.

Evidence of profiled hemodialysis efficacy in the treatment of intradialytic hypotension / Coli L.; La Manna G.; Dalmastri V.; De Pascalis A.; Pace G.; Santese G.; Stefanio C.; Ursino M.; Zaca F.; Stefoni S.. - In: INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. - ISSN 0391-3988. - ELETTRONICO. - 21:7(1998), pp. 398-402. [10.1177/039139889802100703]

Evidence of profiled hemodialysis efficacy in the treatment of intradialytic hypotension

La Manna G.;Dalmastri V.;Pace G.;Ursino M.;Stefoni S.
1998

Abstract

In the last 10 years the percentage of dialysis patients suffering from clinical intradialytic intolerance has greatly increased. Profiled hemodialysis (PHD) is a new technical approach, alternative to standard hemodialysis (SHD) for the treatment of intradialytic symptomatic hypotension. It is based on intradialytic modulation of the dialysate sodium concentration, using a dialysate sodium concentration profile elaborated by a new mathematical kinetic model. The aim of PHD is to reduce the intradialytic blood volume decrease, thanks to a dialysate sodium profile, which allows a reduction in the plasma osmolarity decrease, thereby boosting intravascular fluid refilling. This work aims at clinically validating the PHD technique, by testing its ability, against SLID, to maintain a more stable intradialytic blood volume; this evaluation was supported by monitoring some hemodynamic parameters. Twelve dialysis patients on SHD treatment were selected because of their intradialytic symptomatic hypotension. Twelve SHD (one per patient) and 12 PHD sessions (one per patient) were performed to achieve the same sodium mass removal and body weight decrease on both PHD and SHD. During these sessions we monitored the blood volume variation % by the crit-line (a non invasive blood volume monitoring device), the mean blood pressure and heart rate directly and, finally, the stroke volume and cardiac output indirectly by bidimensional doppler-echocardiography comparison of the results obtained with the two techniques shows PHD to achieve a significantly more stable blood volume, blood pressure and cardiovascular function than SHD, in particular during the second and the third hour of the dialysis session.
1998
Evidence of profiled hemodialysis efficacy in the treatment of intradialytic hypotension / Coli L.; La Manna G.; Dalmastri V.; De Pascalis A.; Pace G.; Santese G.; Stefanio C.; Ursino M.; Zaca F.; Stefoni S.. - In: INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. - ISSN 0391-3988. - ELETTRONICO. - 21:7(1998), pp. 398-402. [10.1177/039139889802100703]
Coli L.; La Manna G.; Dalmastri V.; De Pascalis A.; Pace G.; Santese G.; Stefanio C.; Ursino M.; Zaca F.; Stefoni S.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/960155
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? ND
social impact