An increasing amount of sensor applications require multiple data acquisition with high resolution in truly parallel fashion. This requirement is particularly useful in the field of Nanotechnology where concurrent acquisition is required to understand the correlation between weak stochastic events. In this paper, we will propose a sensor array readout approach where synchronous sigma-delta converters are interfacing each sensing point and whose outputs are concurrently downsampled by dedicated hardware for decimation processing. The approach shows the following advantages: on the one hand the sigma-delta conversion ensures high resolution and linearity (>12 bits), on the other, the 1-bit output allows easier routing access to the array. The approach is particularly useful in the presence of very low signals where direct raster-mode switching access to the array would compromise the signal-to-noise ratio of the readout process. As a proof of this concept, the approach is applied to an array of lipid bilayer membranes (BLMs) permitting to acquire and display single molecule event data by means of a PC-based graphical user interface (GUI).

Concurrent Acquisition Approach for High Resolution Sensor Arrays

THEI, FEDERICO;BENNATI, MARCO;ROSSI, MICHELE;CRESCENTINI, MARCO;TARTAGNI, MARCO
2010

Abstract

An increasing amount of sensor applications require multiple data acquisition with high resolution in truly parallel fashion. This requirement is particularly useful in the field of Nanotechnology where concurrent acquisition is required to understand the correlation between weak stochastic events. In this paper, we will propose a sensor array readout approach where synchronous sigma-delta converters are interfacing each sensing point and whose outputs are concurrently downsampled by dedicated hardware for decimation processing. The approach shows the following advantages: on the one hand the sigma-delta conversion ensures high resolution and linearity (>12 bits), on the other, the 1-bit output allows easier routing access to the array. The approach is particularly useful in the presence of very low signals where direct raster-mode switching access to the array would compromise the signal-to-noise ratio of the readout process. As a proof of this concept, the approach is applied to an array of lipid bilayer membranes (BLMs) permitting to acquire and display single molecule event data by means of a PC-based graphical user interface (GUI).
2010
Proceedings of SENSORDEVICES 2010
94
99
F.Thei; M. Bennati; M. Rossi; M. Crescentini; M. Tartagni
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/92055
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact