The objective of the study was to ascertain residual water levels in polylactide and polylactide-co-glycolide microspheres prepared using the solvent evaporation technique and to investigate the effects of that water on the glass transitional behaviour of the microspheres. Microspheres were prepared from polylactic acid (PLA) and polylactide-co-glycolide (PLGA) 50:50 and 75:25 using a standard solvent evaporation technique. The glass transition was measured as a function of drying conditions using modulated temperature DSC. The microspheres were found to contain very low levels of dichloromethane, while residual water levels of up to circa 3% w/w were noted after freeze or oven drying, these levels being higher for microspheres containing higher glycolic acid levels. The residual water was found to lower the Tg following the Gordon-Taylor relationship. The data indicate that the microparticles may retain significant water levels following standard preparation and drying protocols and that this drying may markedly lower the Tg of the spheres. © 2001 Elsevier Science B.V.

An investigation into the effects of residual water on the glass transition temperature of polylactide microspheres using modulated temperature DSC / Passerini N.; Craig D.Q.M.. - In: JOURNAL OF CONTROLLED RELEASE. - ISSN 0168-3659. - STAMPA. - 73:1(2001), pp. 111-115. [10.1016/S0168-3659(01)00245-0]

An investigation into the effects of residual water on the glass transition temperature of polylactide microspheres using modulated temperature DSC

Passerini N.
Primo
;
2001

Abstract

The objective of the study was to ascertain residual water levels in polylactide and polylactide-co-glycolide microspheres prepared using the solvent evaporation technique and to investigate the effects of that water on the glass transitional behaviour of the microspheres. Microspheres were prepared from polylactic acid (PLA) and polylactide-co-glycolide (PLGA) 50:50 and 75:25 using a standard solvent evaporation technique. The glass transition was measured as a function of drying conditions using modulated temperature DSC. The microspheres were found to contain very low levels of dichloromethane, while residual water levels of up to circa 3% w/w were noted after freeze or oven drying, these levels being higher for microspheres containing higher glycolic acid levels. The residual water was found to lower the Tg following the Gordon-Taylor relationship. The data indicate that the microparticles may retain significant water levels following standard preparation and drying protocols and that this drying may markedly lower the Tg of the spheres. © 2001 Elsevier Science B.V.
2001
An investigation into the effects of residual water on the glass transition temperature of polylactide microspheres using modulated temperature DSC / Passerini N.; Craig D.Q.M.. - In: JOURNAL OF CONTROLLED RELEASE. - ISSN 0168-3659. - STAMPA. - 73:1(2001), pp. 111-115. [10.1016/S0168-3659(01)00245-0]
Passerini N.; Craig D.Q.M.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/882746
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 125
  • ???jsp.display-item.citation.isi??? 120
social impact