Low-Power Instrument Transformers (LPITs) are becoming the first choice for distributed measurement systems for medium voltage networks. However, there are still a lot of challenges related to their operation. Such challenges include their accuracy variation when several influence quantities are acting on them. Among the most significant influence quantities are temperature, electromagnetic field, humidity, etc. Another aspect that increases the importance of studying the LPITs’ accuracy behavior is that, once installed, they cannot be calibrated for several years; hence, one cannot compensate for in-field conditions. Hence, this work aims at introducing a simple type test for a specific LPIT, the Rogowski coil. First, an experimental setup to assess the effect of temperature, humidity, and positioning on the power quality accuracy performance of the Rogowski coil is described. Second, from the results and the experience of the authors it has been possible to design a specific type test. The test has the aim of finding the limits of the accuracy variations of a single Rogowski coil. Afterwards, such limits can be used to compensate for the in-field measurements, obtaining an overall higher accuracy. The results of this work may contribute to the alwaysevolving standardization work on LPITs.

Accuracy Type Test for Rogowski Coils Subjected to Distorted Signals, Temperature, Humidity, and Position Variations

Mingotti A.
Primo
;
Costa F.
Secondo
;
Peretto L.
Penultimo
;
Tinarelli R.
Ultimo
2022

Abstract

Low-Power Instrument Transformers (LPITs) are becoming the first choice for distributed measurement systems for medium voltage networks. However, there are still a lot of challenges related to their operation. Such challenges include their accuracy variation when several influence quantities are acting on them. Among the most significant influence quantities are temperature, electromagnetic field, humidity, etc. Another aspect that increases the importance of studying the LPITs’ accuracy behavior is that, once installed, they cannot be calibrated for several years; hence, one cannot compensate for in-field conditions. Hence, this work aims at introducing a simple type test for a specific LPIT, the Rogowski coil. First, an experimental setup to assess the effect of temperature, humidity, and positioning on the power quality accuracy performance of the Rogowski coil is described. Second, from the results and the experience of the authors it has been possible to design a specific type test. The test has the aim of finding the limits of the accuracy variations of a single Rogowski coil. Afterwards, such limits can be used to compensate for the in-field measurements, obtaining an overall higher accuracy. The results of this work may contribute to the alwaysevolving standardization work on LPITs.
2022
Mingotti A.; Costa F.; Peretto L.; Tinarelli R.
File in questo prodotto:
File Dimensione Formato  
sensors-22-01397-v2.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Creative commons
Dimensione 7.06 MB
Formato Adobe PDF
7.06 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/866421
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact