Objectives: To evaluate the effects of microorganisms’ contamination inside the dispensing syringes of different types of resin-based composites (RBCs). Methods: This study encompassed two sections. First, an anonymous electronic survey was submitted via Google forms to Italian dentists to acquire information about composite handling during clinical procedures. Then, a bench test was performed on nanohybrid RBCs differing in matrix chemistry and fillers [FiltekTM Supreme XTE (3MTM); Venus Pearl (Kulzer GmbH); Admira Fusion x-tra (Voco)] to evaluate the microbial viability on their surfaces with/out photocuring. Uncured RBCs were exposed to standardized inocula of Streptococcus Mutans, Candida Albicans, Lactobacillus Rhamnosus, or mixt plaque in an in vitro model reproducing clinical restorative procedures. Half of the RBC specimens were cured after exposure. Microbial viability was assessed using an MTT-based test. Statistical analysis included three-way ANOVA and Tukey's tests (p<0.05). Results: Among 300 dentists completing the survey, the majority declared to use the spatula to carry the RBCs from the syringe to the dental cavity (50% same spatula; 35% two spatulas). However, 80% of respondents had personal feelings that using one spatula could be a source of cross-contamination. In vitro results using one spatula showed microbial contamination of all RBCs after one hour of storage. The contamination levels depended on the used strain and RBC type (p<0.0001), but photocuring did not reduce contamination (p = 0.2992). Conclusions: Microbial species’ viability on uncured RBCs and after photocuring shows the existence of a considerable risk of cross-infection. Clinical procedures in Restorative Dentistry need to acknowledge and to reduce such risk during RBCs handling. Clinical significance: Dentists must be aware of the possibility of cross-infection during restorative procedures, especially when the same spatula is repeatedly used for placing RBC in the cavity.

Microbial contamination of resin composites inside their dispensers: An increased risk of cross-infection? / Mazzitelli C.; Ionescu A.; Josic U.; Brambilla E.; Breschi L.; Mazzoni A.. - In: JOURNAL OF DENTISTRY. - ISSN 0300-5712. - STAMPA. - 116:(2022), pp. 103893.1-103893.8. [10.1016/j.jdent.2021.103893]

Microbial contamination of resin composites inside their dispensers: An increased risk of cross-infection?

Mazzitelli C.;Josic U.;Breschi L.;Mazzoni A.
2022

Abstract

Objectives: To evaluate the effects of microorganisms’ contamination inside the dispensing syringes of different types of resin-based composites (RBCs). Methods: This study encompassed two sections. First, an anonymous electronic survey was submitted via Google forms to Italian dentists to acquire information about composite handling during clinical procedures. Then, a bench test was performed on nanohybrid RBCs differing in matrix chemistry and fillers [FiltekTM Supreme XTE (3MTM); Venus Pearl (Kulzer GmbH); Admira Fusion x-tra (Voco)] to evaluate the microbial viability on their surfaces with/out photocuring. Uncured RBCs were exposed to standardized inocula of Streptococcus Mutans, Candida Albicans, Lactobacillus Rhamnosus, or mixt plaque in an in vitro model reproducing clinical restorative procedures. Half of the RBC specimens were cured after exposure. Microbial viability was assessed using an MTT-based test. Statistical analysis included three-way ANOVA and Tukey's tests (p<0.05). Results: Among 300 dentists completing the survey, the majority declared to use the spatula to carry the RBCs from the syringe to the dental cavity (50% same spatula; 35% two spatulas). However, 80% of respondents had personal feelings that using one spatula could be a source of cross-contamination. In vitro results using one spatula showed microbial contamination of all RBCs after one hour of storage. The contamination levels depended on the used strain and RBC type (p<0.0001), but photocuring did not reduce contamination (p = 0.2992). Conclusions: Microbial species’ viability on uncured RBCs and after photocuring shows the existence of a considerable risk of cross-infection. Clinical procedures in Restorative Dentistry need to acknowledge and to reduce such risk during RBCs handling. Clinical significance: Dentists must be aware of the possibility of cross-infection during restorative procedures, especially when the same spatula is repeatedly used for placing RBC in the cavity.
2022
Microbial contamination of resin composites inside their dispensers: An increased risk of cross-infection? / Mazzitelli C.; Ionescu A.; Josic U.; Brambilla E.; Breschi L.; Mazzoni A.. - In: JOURNAL OF DENTISTRY. - ISSN 0300-5712. - STAMPA. - 116:(2022), pp. 103893.1-103893.8. [10.1016/j.jdent.2021.103893]
Mazzitelli C.; Ionescu A.; Josic U.; Brambilla E.; Breschi L.; Mazzoni A.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/863314
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4