In order to control cable-driven parallel robots (CDPRs), it is necessary to keep all cable tensions within (positive) known limits during motion. For CDPRs having more cables than end-effector degrees of freedom, a feasible force distribution within cables should be computed beforehand. This paper aims at evaluating how a tension error in one cable affects the overall distribution of tensions in the other cables, by focusing on planar overconstrained CDPRs with four cables. The cable whose tension error more limitedly impact the force distribution is analytically determined by computing the right nullspace of the manipulator structure matrix. It is then shown how the cable least influencing the force distribution changes throughout the wrench-feasible workspace. Lastly, the results of the proposed analysis are used to perform a motion-control experiment on a prototype, where, for any configuration of the end-effector, the cable least influencing the force distribution is tension-controlled, while the remaining ones are length-controlled.

Force-Distribution Sensitivity to Cable-Tension Errors: A Preliminary Investigation / Mattioni V.; Ida E.; Carricato M.. - STAMPA. - 104:(2021), pp. 129-141. [10.1007/978-3-030-75789-2_11]

Force-Distribution Sensitivity to Cable-Tension Errors: A Preliminary Investigation

Mattioni V.
;
Ida E.;Carricato M.
2021

Abstract

In order to control cable-driven parallel robots (CDPRs), it is necessary to keep all cable tensions within (positive) known limits during motion. For CDPRs having more cables than end-effector degrees of freedom, a feasible force distribution within cables should be computed beforehand. This paper aims at evaluating how a tension error in one cable affects the overall distribution of tensions in the other cables, by focusing on planar overconstrained CDPRs with four cables. The cable whose tension error more limitedly impact the force distribution is analytically determined by computing the right nullspace of the manipulator structure matrix. It is then shown how the cable least influencing the force distribution changes throughout the wrench-feasible workspace. Lastly, the results of the proposed analysis are used to perform a motion-control experiment on a prototype, where, for any configuration of the end-effector, the cable least influencing the force distribution is tension-controlled, while the remaining ones are length-controlled.
2021
Cable-Driven Parallel Robots - Proceedings of the 5th International Conference on Cable-Driven Parallel Robots
129
141
Force-Distribution Sensitivity to Cable-Tension Errors: A Preliminary Investigation / Mattioni V.; Ida E.; Carricato M.. - STAMPA. - 104:(2021), pp. 129-141. [10.1007/978-3-030-75789-2_11]
Mattioni V.; Ida E.; Carricato M.
File in questo prodotto:
File Dimensione Formato  
Mattioni-Ida-Carricato_CableCon2021_published.pdf

accesso riservato

Descrizione: Full-text published article
Tipo: Versione (PDF) editoriale
Licenza: Licenza per accesso riservato
Dimensione 1.84 MB
Formato Adobe PDF
1.84 MB Adobe PDF   Visualizza/Apri   Contatta l'autore
Mattioni_Ida_Carricato_CableCon2021-pp.pdf

Open Access dal 01/06/2022

Tipo: Postprint
Licenza: Licenza per accesso libero gratuito
Dimensione 3.21 MB
Formato Adobe PDF
3.21 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/826615
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? ND
social impact