Purpose: The main purpose and research question of the study are to compare the efficacy of high-security closed versus open devices for human oocytes’ vitrification. Methods: A prospective randomized study was conducted. A total of 737 patients attending the Infertility and IVF Unit at S.Orsola University Hospital (Italy) between October 2015 and April 2020 were randomly assigned to two groups. A total of 368 patients were assigned to group 1 (High-Security Vitrification™ - HSV) and 369 to group 2 (Cryotop® open system). Oocyte survival, fertilization, cleavage, pregnancy, implantation, and miscarriage rate were compared between the two groups. Results: No statistically significant differences were observed on survival rate (70.3% vs. 73.3%), fertilization rate (70.8% vs. 74.9%), cleavage rate (90.6% vs. 90.3%), pregnancy/transfer ratio (32.0% vs. 31.8%), implantation rate (19.7% vs. 19.9%), nor miscarriage rates (22.1% vs. 21.5%) between the two groups. Women’s mean age in group 1 (36.18 ± 3.92) and group 2 (35.88 ± 3.88) was not significantly different (P =.297). A total of 4029 oocytes were vitrified (1980 and 2049 in groups 1 and 2 respectively). A total of 2564 were warmed (1469 and 1095 in groups 1 and 2 respectively). A total of 1386 morphologically eligible oocytes were inseminated by intracytoplasmic sperm injection (792 and 594 respectively, P =.304). Conclusions: The present study shows that the replacement of the open vitrification system by a closed one has no impact on in vitro and in vivo survival, development, pregnancy and implantation rate. Furthermore, to ensure safety, especially during the current COVID-19 pandemic, the use of the closed device eliminates the potential samples’ contamination during vitrification and storage.

High-security closed devices are efficient and safe to protect human oocytes from potential risk of viral contamination during vitrification and storage especially in the COVID-19 pandemic / Porcu E.; Tranquillo M.L.; Notarangelo L.; Ciotti P.M.; Calza N.; Zuffa S.; Mori L.; Nardi E.; Dirodi M.; Cipriani L.; Labriola F.S.; Damiano G.. - In: JOURNAL OF ASSISTED REPRODUCTION AND GENETICS. - ISSN 1058-0468. - ELETTRONICO. - 38:3(2021), pp. 681-688. [10.1007/s10815-021-02062-y]

High-security closed devices are efficient and safe to protect human oocytes from potential risk of viral contamination during vitrification and storage especially in the COVID-19 pandemic

Porcu E.
Primo
;
Notarangelo L.;Ciotti P. M.;Nardi E.;Dirodi M.;Cipriani L.;Labriola F. S.;Damiano G.
2021

Abstract

Purpose: The main purpose and research question of the study are to compare the efficacy of high-security closed versus open devices for human oocytes’ vitrification. Methods: A prospective randomized study was conducted. A total of 737 patients attending the Infertility and IVF Unit at S.Orsola University Hospital (Italy) between October 2015 and April 2020 were randomly assigned to two groups. A total of 368 patients were assigned to group 1 (High-Security Vitrification™ - HSV) and 369 to group 2 (Cryotop® open system). Oocyte survival, fertilization, cleavage, pregnancy, implantation, and miscarriage rate were compared between the two groups. Results: No statistically significant differences were observed on survival rate (70.3% vs. 73.3%), fertilization rate (70.8% vs. 74.9%), cleavage rate (90.6% vs. 90.3%), pregnancy/transfer ratio (32.0% vs. 31.8%), implantation rate (19.7% vs. 19.9%), nor miscarriage rates (22.1% vs. 21.5%) between the two groups. Women’s mean age in group 1 (36.18 ± 3.92) and group 2 (35.88 ± 3.88) was not significantly different (P =.297). A total of 4029 oocytes were vitrified (1980 and 2049 in groups 1 and 2 respectively). A total of 2564 were warmed (1469 and 1095 in groups 1 and 2 respectively). A total of 1386 morphologically eligible oocytes were inseminated by intracytoplasmic sperm injection (792 and 594 respectively, P =.304). Conclusions: The present study shows that the replacement of the open vitrification system by a closed one has no impact on in vitro and in vivo survival, development, pregnancy and implantation rate. Furthermore, to ensure safety, especially during the current COVID-19 pandemic, the use of the closed device eliminates the potential samples’ contamination during vitrification and storage.
2021
High-security closed devices are efficient and safe to protect human oocytes from potential risk of viral contamination during vitrification and storage especially in the COVID-19 pandemic / Porcu E.; Tranquillo M.L.; Notarangelo L.; Ciotti P.M.; Calza N.; Zuffa S.; Mori L.; Nardi E.; Dirodi M.; Cipriani L.; Labriola F.S.; Damiano G.. - In: JOURNAL OF ASSISTED REPRODUCTION AND GENETICS. - ISSN 1058-0468. - ELETTRONICO. - 38:3(2021), pp. 681-688. [10.1007/s10815-021-02062-y]
Porcu E.; Tranquillo M.L.; Notarangelo L.; Ciotti P.M.; Calza N.; Zuffa S.; Mori L.; Nardi E.; Dirodi M.; Cipriani L.; Labriola F.S.; Damiano G.
File in questo prodotto:
File Dimensione Formato  
Porcu2021_Article_High-securityClosedDevicesAreE(1).pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 290.06 kB
Formato Adobe PDF
290.06 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/806785
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 12
social impact