This work presents a wideband active load pull setup for active device characterization under modulated excitations. The setup, differently from approaches requiring full waveform acquisition capabilities, uses standard vector network analyzer measurements. The secants' method is used to iteratively find the output injected signal to synthesize the target load profile. A linear pre-compensation of the large signal output match of the device under test is proposed in order to significantly improve convergence speed and stability of the method. Performance results for the proposed approach are reported for a power amplifier and a Gallium Nitride HEMT for a 80MHz modulation bandwidth in the 1-6 GHz range.

Enhanced wideband active load-pull with a vector network analyzer using modulated excitations and device output match compensation / Angelotti A.M.; Gibiino G.P.; Nielsen T.S.; Schreurs D.; Santarelli A.. - ELETTRONICO. - 2020-:(2020), pp. 9223947.763-9223947.766. (Intervento presentato al convegno 2020 IEEE/MTT-S International Microwave Symposium, IMS 2020 tenutosi a usa nel 2020) [10.1109/IMS30576.2020.9223947].

Enhanced wideband active load-pull with a vector network analyzer using modulated excitations and device output match compensation

Angelotti A. M.;Gibiino G. P.;Santarelli A.
2020

Abstract

This work presents a wideband active load pull setup for active device characterization under modulated excitations. The setup, differently from approaches requiring full waveform acquisition capabilities, uses standard vector network analyzer measurements. The secants' method is used to iteratively find the output injected signal to synthesize the target load profile. A linear pre-compensation of the large signal output match of the device under test is proposed in order to significantly improve convergence speed and stability of the method. Performance results for the proposed approach are reported for a power amplifier and a Gallium Nitride HEMT for a 80MHz modulation bandwidth in the 1-6 GHz range.
2020
IEEE MTT-S International Microwave Symposium Digest
763
766
Enhanced wideband active load-pull with a vector network analyzer using modulated excitations and device output match compensation / Angelotti A.M.; Gibiino G.P.; Nielsen T.S.; Schreurs D.; Santarelli A.. - ELETTRONICO. - 2020-:(2020), pp. 9223947.763-9223947.766. (Intervento presentato al convegno 2020 IEEE/MTT-S International Microwave Symposium, IMS 2020 tenutosi a usa nel 2020) [10.1109/IMS30576.2020.9223947].
Angelotti A.M.; Gibiino G.P.; Nielsen T.S.; Schreurs D.; Santarelli A.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.