The long-term performance of double U-tube Borehole Heat Exchangers (BHEs) is studied numerically by considering three different time-dependent heat fluxes exchanged between each BHE and the ground. Reference is made to the following geometrical configurations: a single BHE surrounded by infinite ground; a field of 4 BHEs surrounded by infinite ground; the limiting case of a field of infinite BHEs. Since the temperature distribution along the vertical direction has a negligible influence on long-term BHE performance, the problem is studied by means of a 2D conduction model, where the energy transfer due to water flow is replaced by a uniform, time dependent, heat generation. The fluid mean temperature in the BHE is determined as a function of time. Results point out that, in the absence of groundwater movement, when a BHE field is considered, at least a partial compensation of the thermal load is necessary to avoid long-term system breakdown.

Numerical Evaluation of Long-Term Performance of Borehole Heat Exchanger Fields / A. Priarone; S. Lazzari; E. Zanchini. - ELETTRONICO. - (2009). (Intervento presentato al convegno COMSOL Conference 2009 Milan tenutosi a Milan, Italy nel October 14-16 2009).

Numerical Evaluation of Long-Term Performance of Borehole Heat Exchanger Fields

LAZZARI, STEFANO;ZANCHINI, ENZO
2009

Abstract

The long-term performance of double U-tube Borehole Heat Exchangers (BHEs) is studied numerically by considering three different time-dependent heat fluxes exchanged between each BHE and the ground. Reference is made to the following geometrical configurations: a single BHE surrounded by infinite ground; a field of 4 BHEs surrounded by infinite ground; the limiting case of a field of infinite BHEs. Since the temperature distribution along the vertical direction has a negligible influence on long-term BHE performance, the problem is studied by means of a 2D conduction model, where the energy transfer due to water flow is replaced by a uniform, time dependent, heat generation. The fluid mean temperature in the BHE is determined as a function of time. Results point out that, in the absence of groundwater movement, when a BHE field is considered, at least a partial compensation of the thermal load is necessary to avoid long-term system breakdown.
2009
Proceedings of COMSOL Conference 2009 Milan
Numerical Evaluation of Long-Term Performance of Borehole Heat Exchanger Fields / A. Priarone; S. Lazzari; E. Zanchini. - ELETTRONICO. - (2009). (Intervento presentato al convegno COMSOL Conference 2009 Milan tenutosi a Milan, Italy nel October 14-16 2009).
A. Priarone; S. Lazzari; E. Zanchini
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/80485
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact