The goal of this work was to improve the image quality of small animal PET images by introducing in the reconstruction process the true system point spread function (PSF) and an anatomical image prior. Simulations were performed using a mouse heart phantom (myocardium and ventricles) and a comparison between standard EM reconstruction and EM with PSF modelling and anatomical prior was performed. The system PSF was assumed to be a Gaussian function and its Full Width Half Maximum (FWHM) was modelled to be spatially variant in order to simulate the different spatial resolution inside the scanner field of view. A visual comparison of the images reconstructed with the standard EM and with the proposed image reconstruction method showed that the reconstructed images look much sharper and are very close to the true ones when using EM with PSF modelling and anatomical prior.

Iterative EM Reconstruction of Cardiac Small Animal PET Images Using System Point Spread Function Modelling and MAP with Anatomical Priors / AE Spinelli; G Fiacchi; D D’Ambrosio; P Cilibrizzi; C Lamberti; G Baldazzi; S Boschi; R Franchi; M Marengo. - In: COMPUTERS IN CARDIOLOGY. - ISSN 0276-6574. - ELETTRONICO. - 35:(2008), pp. 4749046.333-4749046.336. (Intervento presentato al convegno Computers in Cardiology 2008 tenutosi a Bologna nel 14-17 Settembre 2008) [10.1109/CIC.2008.4749046].

Iterative EM Reconstruction of Cardiac Small Animal PET Images Using System Point Spread Function Modelling and MAP with Anatomical Priors

LAMBERTI, CLAUDIO;BALDAZZI, GIUSEPPE;FRANCHI, ROBERTO
2008

Abstract

The goal of this work was to improve the image quality of small animal PET images by introducing in the reconstruction process the true system point spread function (PSF) and an anatomical image prior. Simulations were performed using a mouse heart phantom (myocardium and ventricles) and a comparison between standard EM reconstruction and EM with PSF modelling and anatomical prior was performed. The system PSF was assumed to be a Gaussian function and its Full Width Half Maximum (FWHM) was modelled to be spatially variant in order to simulate the different spatial resolution inside the scanner field of view. A visual comparison of the images reconstructed with the standard EM and with the proposed image reconstruction method showed that the reconstructed images look much sharper and are very close to the true ones when using EM with PSF modelling and anatomical prior.
2008
35th Annual Conference on Computers in Cardiology
333
336
Iterative EM Reconstruction of Cardiac Small Animal PET Images Using System Point Spread Function Modelling and MAP with Anatomical Priors / AE Spinelli; G Fiacchi; D D’Ambrosio; P Cilibrizzi; C Lamberti; G Baldazzi; S Boschi; R Franchi; M Marengo. - In: COMPUTERS IN CARDIOLOGY. - ISSN 0276-6574. - ELETTRONICO. - 35:(2008), pp. 4749046.333-4749046.336. (Intervento presentato al convegno Computers in Cardiology 2008 tenutosi a Bologna nel 14-17 Settembre 2008) [10.1109/CIC.2008.4749046].
AE Spinelli; G Fiacchi; D D’Ambrosio; P Cilibrizzi; C Lamberti; G Baldazzi; S Boschi; R Franchi; M Marengo
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/80097
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact