Total elbow arthroplasty (TEA) is an effective and frequently used treatment for patients with debilitating elbow pathology. Total elbow prostheses have lagged behind those of the knee, hip and shoulder for different reasons, such as the high failure rate of the early designs. Concern remains regarding the longevity of TEA implants, especially in younger patients. The main cause of revision of the implant is usually related to the phenomenon of aseptic loosening mainly due to the cement-bone interface failure. Aim of this work is the biomechanical analysis of a new elbow prosthesis to investigate the mechanical behaviour at the cement-bone interface. For this reason, a musculoskeletal model has been developed by modelling the forces of the muscles and after FEM analyses have been performed. Obtained results confirm the validity of the implemented model and can provide guidelines for surgeons regarding the implant configurations with the aim to reduce the aseptic loosening.

Biomechanical Analysis of a New Elbow Prosthesis / Ricotta V.; Bragonzoni L.; Marannano G.; Nalbone L.; Valenti A.. - ELETTRONICO. - (2020), pp. 812-823. (Intervento presentato al convegno International Conference on Design Tools and Methods in Industrial Engineering, ADM 2019 tenutosi a ita nel 2019) [10.1007/978-3-030-31154-4_69].

Biomechanical Analysis of a New Elbow Prosthesis

Bragonzoni L.;
2020

Abstract

Total elbow arthroplasty (TEA) is an effective and frequently used treatment for patients with debilitating elbow pathology. Total elbow prostheses have lagged behind those of the knee, hip and shoulder for different reasons, such as the high failure rate of the early designs. Concern remains regarding the longevity of TEA implants, especially in younger patients. The main cause of revision of the implant is usually related to the phenomenon of aseptic loosening mainly due to the cement-bone interface failure. Aim of this work is the biomechanical analysis of a new elbow prosthesis to investigate the mechanical behaviour at the cement-bone interface. For this reason, a musculoskeletal model has been developed by modelling the forces of the muscles and after FEM analyses have been performed. Obtained results confirm the validity of the implemented model and can provide guidelines for surgeons regarding the implant configurations with the aim to reduce the aseptic loosening.
2020
Lecture Notes in Mechanical Engineering
812
823
Biomechanical Analysis of a New Elbow Prosthesis / Ricotta V.; Bragonzoni L.; Marannano G.; Nalbone L.; Valenti A.. - ELETTRONICO. - (2020), pp. 812-823. (Intervento presentato al convegno International Conference on Design Tools and Methods in Industrial Engineering, ADM 2019 tenutosi a ita nel 2019) [10.1007/978-3-030-31154-4_69].
Ricotta V.; Bragonzoni L.; Marannano G.; Nalbone L.; Valenti A.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/800484
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact