68Ga-labeled urea-based inhibitors of the prostate-specific membrane antigen (PSMA), such as 68Ga-PSMA-11, are promising small molecules for targeting prostate cancer (PCa). Although this radiopharmaceutical was produced mostly by means of manual synthesis and automated synthesis modules, a sterile cold kit was recently introduced. The aim of our study was to evaluate the image quality of 68Ga-PSMA-11 PET/CT (PSMA-PET) in a population of PCa patients after the injection of comparable activities of 68Ga-PSMA-11 obtained with the 2 different synthetic procedures. A secondary aim was to identify secondary factors that may have an impact on image quality and, thus, final interpretation. Methods: Two different groups of 100 consecutive PCa patients who underwent PSMA-PET were included in the study. The first group of patients was imaged with 68Ga-PSMA-11 obtained using synthesis modules, whereas the second group's tracer activity was synthesized using a sterile cold kit. All PET images were independently reviewed by 2 nuclear medicine diagnosticians with at least 2 y of experience in PSMA-based imaging and unaware of the patients' clinical history. The 2 reviewers independently rated the quality of each PSMA-PET scan using a 3-point Likert-type scale. In cases of discordance, the operators together reviewed the images and reached a consensus. Performance was evaluated on the basis of the expected biodistribution, lesion detection rate, and physiologic background uptake. Results: Overall, 104 of 200 (52%) PSMA-PET scans were positive for PCa-related findings. No significant differences in image quality between cold kits and synthesis modules were found (P = 0.13), although a higher proportion of images was rated as excellent by the observers for kits than for modules (45% vs. 34%). Furthermore, after image quality had been dichotomized as excellent or not excellent, multivariate regression analysis found several factors to be significantly associated with a not-excellent quality: an increase in patient age (+5 y: odds ratio [OR], 1.40; 95% confidence interval [CI], 1.12-1.75), an increase in patient weight (+5 kg: OR, 1.89; 95% CI, 1.53-2.32), an increase in 68Ga-PSMA-11 uptake time (+10 min: OR, 1.45; 95% CI, 1.08-1.96), and a decrease in injected activity (-10 MBq: OR, 1.28; 95% CI, 1.07-1.52). Conclusion: No significant differences were identified between the 2 groups of patients undergoing PSMA-PET; therefore, we were not able to ascertain any significant influences of tracer production methodology on final scan quality. However, increased patient age, increased patient weight, decreased injected activity, and increased 68Ga-PSMA-11 uptake time were significantly associated with an overall poorer image quality.

Evaluation of an Automated Module Synthesis and a Sterile Cold Kit-Based Preparation of 68Ga-PSMA-11 in Patients with Prostate Cancer / Calderoni L, Farolfi A, Pianori D, Maietti E, Cabitza V, Lambertini A, Ricci G, Telo S, Lodi F, Castellucci P, Fanti S.. - In: THE JOURNAL OF NUCLEAR MEDICINE. - ISSN 0161-5505. - STAMPA. - 61:(2020), pp. 716-722. [10.2967/jnumed.119.231605]

Evaluation of an Automated Module Synthesis and a Sterile Cold Kit-Based Preparation of 68Ga-PSMA-11 in Patients with Prostate Cancer.

Farolfi A;Pianori D;Maietti E;Cabitza V;Telo S;Castellucci P;Fanti S.
2020

Abstract

68Ga-labeled urea-based inhibitors of the prostate-specific membrane antigen (PSMA), such as 68Ga-PSMA-11, are promising small molecules for targeting prostate cancer (PCa). Although this radiopharmaceutical was produced mostly by means of manual synthesis and automated synthesis modules, a sterile cold kit was recently introduced. The aim of our study was to evaluate the image quality of 68Ga-PSMA-11 PET/CT (PSMA-PET) in a population of PCa patients after the injection of comparable activities of 68Ga-PSMA-11 obtained with the 2 different synthetic procedures. A secondary aim was to identify secondary factors that may have an impact on image quality and, thus, final interpretation. Methods: Two different groups of 100 consecutive PCa patients who underwent PSMA-PET were included in the study. The first group of patients was imaged with 68Ga-PSMA-11 obtained using synthesis modules, whereas the second group's tracer activity was synthesized using a sterile cold kit. All PET images were independently reviewed by 2 nuclear medicine diagnosticians with at least 2 y of experience in PSMA-based imaging and unaware of the patients' clinical history. The 2 reviewers independently rated the quality of each PSMA-PET scan using a 3-point Likert-type scale. In cases of discordance, the operators together reviewed the images and reached a consensus. Performance was evaluated on the basis of the expected biodistribution, lesion detection rate, and physiologic background uptake. Results: Overall, 104 of 200 (52%) PSMA-PET scans were positive for PCa-related findings. No significant differences in image quality between cold kits and synthesis modules were found (P = 0.13), although a higher proportion of images was rated as excellent by the observers for kits than for modules (45% vs. 34%). Furthermore, after image quality had been dichotomized as excellent or not excellent, multivariate regression analysis found several factors to be significantly associated with a not-excellent quality: an increase in patient age (+5 y: odds ratio [OR], 1.40; 95% confidence interval [CI], 1.12-1.75), an increase in patient weight (+5 kg: OR, 1.89; 95% CI, 1.53-2.32), an increase in 68Ga-PSMA-11 uptake time (+10 min: OR, 1.45; 95% CI, 1.08-1.96), and a decrease in injected activity (-10 MBq: OR, 1.28; 95% CI, 1.07-1.52). Conclusion: No significant differences were identified between the 2 groups of patients undergoing PSMA-PET; therefore, we were not able to ascertain any significant influences of tracer production methodology on final scan quality. However, increased patient age, increased patient weight, decreased injected activity, and increased 68Ga-PSMA-11 uptake time were significantly associated with an overall poorer image quality.
2020
Evaluation of an Automated Module Synthesis and a Sterile Cold Kit-Based Preparation of 68Ga-PSMA-11 in Patients with Prostate Cancer / Calderoni L, Farolfi A, Pianori D, Maietti E, Cabitza V, Lambertini A, Ricci G, Telo S, Lodi F, Castellucci P, Fanti S.. - In: THE JOURNAL OF NUCLEAR MEDICINE. - ISSN 0161-5505. - STAMPA. - 61:(2020), pp. 716-722. [10.2967/jnumed.119.231605]
Calderoni L, Farolfi A, Pianori D, Maietti E, Cabitza V, Lambertini A, Ricci G, Telo S, Lodi F, Castellucci P, Fanti S.
File in questo prodotto:
File Dimensione Formato  
Calderoni_2020.pdf

accesso riservato

Tipo: Versione (PDF) editoriale
Licenza: Licenza per accesso riservato
Dimensione 830.02 kB
Formato Adobe PDF
830.02 kB Adobe PDF   Visualizza/Apri   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/798504
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 18
social impact