Highly random nature of input power from wave energy converters (WEC), especially from direct-driven point absorbers, demands customized power electronic converters for grid connection. In this paper, analysis and comparison of the DC-link stresses in the converter systems for two cases - a single and three collective units, of wave energy converters is given. The AC/DC/AC converter system includes a conventional uncontrolled three phase rectifier, a DC/DC converter to boost the DC-link voltage and an inverter with RL load. The system has been studied under two different controller actions for the DC/DC converter: with constant boost factor and with constant DC-link voltage. A Proportional Integral controller has been used to regulate the voltage in the latter case. Matlab/Simulink based system simulation has been done to compare the DC-link stress. The analysis shows the comparison in DC-link stresses and the requirements of the system for different cases, proving the advantages and the importance of having customized active power conversion methods for minimizing the DC-link stresses.

DC-link stress analysis for the grid connection of point absorber type wave energy converters / Soman D.E.; Loncarski J.; Srndovic M.; Leijon M.. - ELETTRONICO. - (2015), pp. 7177601.61-7177601.66. (Intervento presentato al convegno 5th International Conference on Clean Electrical Power, ICCEP 2015 tenutosi a ita nel 2015) [10.1109/ICCEP.2015.7177601].

DC-link stress analysis for the grid connection of point absorber type wave energy converters

Loncarski J.;Srndovic M.;
2015

Abstract

Highly random nature of input power from wave energy converters (WEC), especially from direct-driven point absorbers, demands customized power electronic converters for grid connection. In this paper, analysis and comparison of the DC-link stresses in the converter systems for two cases - a single and three collective units, of wave energy converters is given. The AC/DC/AC converter system includes a conventional uncontrolled three phase rectifier, a DC/DC converter to boost the DC-link voltage and an inverter with RL load. The system has been studied under two different controller actions for the DC/DC converter: with constant boost factor and with constant DC-link voltage. A Proportional Integral controller has been used to regulate the voltage in the latter case. Matlab/Simulink based system simulation has been done to compare the DC-link stress. The analysis shows the comparison in DC-link stresses and the requirements of the system for different cases, proving the advantages and the importance of having customized active power conversion methods for minimizing the DC-link stresses.
2015
5th International Conference on Clean Electrical Power: Renewable Energy Resources Impact, ICCEP 2015
61
66
DC-link stress analysis for the grid connection of point absorber type wave energy converters / Soman D.E.; Loncarski J.; Srndovic M.; Leijon M.. - ELETTRONICO. - (2015), pp. 7177601.61-7177601.66. (Intervento presentato al convegno 5th International Conference on Clean Electrical Power, ICCEP 2015 tenutosi a ita nel 2015) [10.1109/ICCEP.2015.7177601].
Soman D.E.; Loncarski J.; Srndovic M.; Leijon M.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/797491
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact