Introduction: Biopsy of affected tissue is required for lymphoma diagnosis and to plan treatment. Open incisional biopsy is traditionally the method of choice. Nevertheless, it requires hospitalization, availability of an operating room, and sometimes general anesthesia, and it is associated with several drawbacks. Fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) can be potentially used to drive biopsy to the most metabolically active area within a lymph node or extranodal masses. Methods: A study of diagnostic accuracy was conducted to assess the performance of a PET-driven needle biopsy in patients with suspect active lymphoma. Results: Overall, 99 procedures have been performed: three (3.0%) were interrupted because of pain but were successfully repeated in two cases. Median SUVmax of target lesions was 10.7. In 84/96 cases, the tissue was considered adequate to formulate a diagnosis (diagnostic yield of 87.5%) and to guide the following clinical decision. The target specimen was a lymph node in 60 cases and an extranodal site in 36. No serious adverse events occurred. The sensitivity of this procedure was 96%, with a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 75%. Conclusion: Patients can benefit from a minimally invasive procedure which allows a timely and accurate diagnosis of lymphoma at onset or relapse.

Diagnostic accuracy of positron emission tomography/computed tomography-driven biopsy for the diagnosis of lymphoma / Broccoli A.; Nanni C.; Cappelli A.; Bacci F.; Gasbarrini A.; Tabacchi E.; Piovani C.; Argnani L.; Ghermandi R.; Sabattini E.; Golfieri R.; Fanti S.; Zinzani P.L.. - In: EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING. - ISSN 1619-7070. - ELETTRONICO. - 47:13(2020), pp. 3058-3065. [10.1007/s00259-020-04913-9]

Diagnostic accuracy of positron emission tomography/computed tomography-driven biopsy for the diagnosis of lymphoma

Broccoli A.
Primo
;
Tabacchi E.;Piovani C.;Argnani L.;Ghermandi R.;Sabattini E.;Golfieri R.;Fanti S.
Penultimo
;
Zinzani P. L.
Ultimo
2020

Abstract

Introduction: Biopsy of affected tissue is required for lymphoma diagnosis and to plan treatment. Open incisional biopsy is traditionally the method of choice. Nevertheless, it requires hospitalization, availability of an operating room, and sometimes general anesthesia, and it is associated with several drawbacks. Fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) can be potentially used to drive biopsy to the most metabolically active area within a lymph node or extranodal masses. Methods: A study of diagnostic accuracy was conducted to assess the performance of a PET-driven needle biopsy in patients with suspect active lymphoma. Results: Overall, 99 procedures have been performed: three (3.0%) were interrupted because of pain but were successfully repeated in two cases. Median SUVmax of target lesions was 10.7. In 84/96 cases, the tissue was considered adequate to formulate a diagnosis (diagnostic yield of 87.5%) and to guide the following clinical decision. The target specimen was a lymph node in 60 cases and an extranodal site in 36. No serious adverse events occurred. The sensitivity of this procedure was 96%, with a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 75%. Conclusion: Patients can benefit from a minimally invasive procedure which allows a timely and accurate diagnosis of lymphoma at onset or relapse.
2020
Diagnostic accuracy of positron emission tomography/computed tomography-driven biopsy for the diagnosis of lymphoma / Broccoli A.; Nanni C.; Cappelli A.; Bacci F.; Gasbarrini A.; Tabacchi E.; Piovani C.; Argnani L.; Ghermandi R.; Sabattini E.; Golfieri R.; Fanti S.; Zinzani P.L.. - In: EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING. - ISSN 1619-7070. - ELETTRONICO. - 47:13(2020), pp. 3058-3065. [10.1007/s00259-020-04913-9]
Broccoli A.; Nanni C.; Cappelli A.; Bacci F.; Gasbarrini A.; Tabacchi E.; Piovani C.; Argnani L.; Ghermandi R.; Sabattini E.; Golfieri R.; Fanti S.; Zinzani P.L.
File in questo prodotto:
File Dimensione Formato  
37. Broccoli.pdf

accesso aperto

Descrizione: Articolo
Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 2.99 MB
Formato Adobe PDF
2.99 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/796829
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact