Purpose Single‐sided 1H‐NMR is proposed for the estimation of morphological parameters of trabecular bone, and potentially the detection of pathophysiological alterations of bone structure. In this study, a new methodology was used to estimate such parameters without using an external reference signal, and to study intratrabecular and intertrabecular porosities, with a view to eventually scanning patients. Methods Animal trabecular bone samples were analyzed by a single‐sided device. The Carr‐Purcell‐Meiboom‐Gill sequence of 1H nuclei of fluids, including marrow, confined inside the bone, was analyzed by quasi‐continuous T2 distributions and separated into two 1H pools: short and long T2 components. The NMR parameters were estimated using models of trabecular bone structure, and compared with the corresponding micro‐CT. Results Without any further assumptions, the internal reference parameter (short T2 signal intensity fraction) enabled prediction of the micro‐CT parameters BV/TV (volume of the trabeculae/total sample volume) and BS/TV (external surface of the trabeculae/total sample volume) with linear correlation coefficient >0.80. The assignment of the two pools to intratrabecular and intertrabecular components yielded an estimate of average intratrabecular porosity (33 ± 5)%. Using the proposed models, the NMR‐estimated BV/TV and BS/TV were found to be linearly related to the corresponding micro‐CT values with high correlation (>0.90 for BV/TV; >0.80 for BS/TV) and agreement coefficients. Conclusion Low‐field, low‐cost portable devices that rely on intrinsic magnetic field gradients and do not use ionizing radiation are viable tools for in vitro preclinical studies of pathophysiological structural alterations of trabecular bone.

Single‐sided NMR to estimate morphological parameters of the trabecular bone structure / Marco Barbieri, Paola Fantazzini, Villiam Bortolotti, Fabio Baruffaldi, Anna Festa, David N. Manners, Claudia Testa, Leonardo Brizi. - In: MAGNETIC RESONANCE IN MEDICINE. - ISSN 0740-3194. - ELETTRONICO. - 85:6(2021), pp. 3353-3369. [10.1002/mrm.28648]

Single‐sided NMR to estimate morphological parameters of the trabecular bone structure

Marco Barbieri;Paola Fantazzini;Villiam Bortolotti;David N. Manners;Claudia Testa;Leonardo Brizi
2021

Abstract

Purpose Single‐sided 1H‐NMR is proposed for the estimation of morphological parameters of trabecular bone, and potentially the detection of pathophysiological alterations of bone structure. In this study, a new methodology was used to estimate such parameters without using an external reference signal, and to study intratrabecular and intertrabecular porosities, with a view to eventually scanning patients. Methods Animal trabecular bone samples were analyzed by a single‐sided device. The Carr‐Purcell‐Meiboom‐Gill sequence of 1H nuclei of fluids, including marrow, confined inside the bone, was analyzed by quasi‐continuous T2 distributions and separated into two 1H pools: short and long T2 components. The NMR parameters were estimated using models of trabecular bone structure, and compared with the corresponding micro‐CT. Results Without any further assumptions, the internal reference parameter (short T2 signal intensity fraction) enabled prediction of the micro‐CT parameters BV/TV (volume of the trabeculae/total sample volume) and BS/TV (external surface of the trabeculae/total sample volume) with linear correlation coefficient >0.80. The assignment of the two pools to intratrabecular and intertrabecular components yielded an estimate of average intratrabecular porosity (33 ± 5)%. Using the proposed models, the NMR‐estimated BV/TV and BS/TV were found to be linearly related to the corresponding micro‐CT values with high correlation (>0.90 for BV/TV; >0.80 for BS/TV) and agreement coefficients. Conclusion Low‐field, low‐cost portable devices that rely on intrinsic magnetic field gradients and do not use ionizing radiation are viable tools for in vitro preclinical studies of pathophysiological structural alterations of trabecular bone.
2021
Single‐sided NMR to estimate morphological parameters of the trabecular bone structure / Marco Barbieri, Paola Fantazzini, Villiam Bortolotti, Fabio Baruffaldi, Anna Festa, David N. Manners, Claudia Testa, Leonardo Brizi. - In: MAGNETIC RESONANCE IN MEDICINE. - ISSN 0740-3194. - ELETTRONICO. - 85:6(2021), pp. 3353-3369. [10.1002/mrm.28648]
Marco Barbieri, Paola Fantazzini, Villiam Bortolotti, Fabio Baruffaldi, Anna Festa, David N. Manners, Claudia Testa, Leonardo Brizi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/786715
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact