An array of proportional-resonant regulators is often used in shunt active power filters to control the grid currents and reduce the harmonic distortion caused by a distorting load. The voltage that is necessary to compensate for the current harmonics must be consistent with the available dc-link voltage. In this article, three adaptive algorithms for the exploitation of the dc-link voltage are developed and compared. These algorithms adaptively change the voltage saturation of each regulator to preserve the control capability of the fundamental component of the current when the available voltage is not enough to control the filter current. Simultaneously, they try to improve the quality of the grid current because the dc-link voltage of the active power filter is allocated to the regulators to compensate only the most significant harmonics. Some experimental results are shown to demonstrate the feasibility of the three algorithms.

Comparison of Three Voltage Saturation Algorithms in Shunt Active Power Filters with Selective Harmonic Control / Amerise A.; Mengoni M.; Rizzoli G.; Zarri L.; Tani A.; Casadei D.. - In: IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS. - ISSN 0093-9994. - STAMPA. - 56:3(2020), pp. 8988204.2762-8988204.2772. [10.1109/TIA.2020.2972853]

Comparison of Three Voltage Saturation Algorithms in Shunt Active Power Filters with Selective Harmonic Control

Amerise A.;Mengoni M.;Rizzoli G.;Zarri L.;Tani A.;Casadei D.
2020

Abstract

An array of proportional-resonant regulators is often used in shunt active power filters to control the grid currents and reduce the harmonic distortion caused by a distorting load. The voltage that is necessary to compensate for the current harmonics must be consistent with the available dc-link voltage. In this article, three adaptive algorithms for the exploitation of the dc-link voltage are developed and compared. These algorithms adaptively change the voltage saturation of each regulator to preserve the control capability of the fundamental component of the current when the available voltage is not enough to control the filter current. Simultaneously, they try to improve the quality of the grid current because the dc-link voltage of the active power filter is allocated to the regulators to compensate only the most significant harmonics. Some experimental results are shown to demonstrate the feasibility of the three algorithms.
2020
Comparison of Three Voltage Saturation Algorithms in Shunt Active Power Filters with Selective Harmonic Control / Amerise A.; Mengoni M.; Rizzoli G.; Zarri L.; Tani A.; Casadei D.. - In: IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS. - ISSN 0093-9994. - STAMPA. - 56:3(2020), pp. 8988204.2762-8988204.2772. [10.1109/TIA.2020.2972853]
Amerise A.; Mengoni M.; Rizzoli G.; Zarri L.; Tani A.; Casadei D.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/758455
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 10
social impact