Brachytherapy is an advanced cancer treatment that is minimally invasive, minimising radiation exposure to the surrounding healthy tissues. Microselectron© Nucletron devices with 192Ir source can be used for gynaecological brachytherapy, in patients with vaginal or uterine cancer. Measurements of isodose curves have been performed in a PMMA phantom and compared with Monte Carlo calculation and TPS (Plato software of Nucletron BPS 14.2) evaluation. The isodose measurements have been performed with radiochromic films (Gafchromic EBT ©). The dose matrix has been obtained after digitalisation and use of a dose calibration curve obtained with a 6MV photon beam provided by a medical linear accelerator. A comparison between the calculated and the measured matrix has been performed. The calculated dose matrix is obtained with a simulation using the MCNP5 Monte Carlo code (F4MESH tally).

MCNP modelling of vaginal and uterine applicators used in intracavitary brachytherapy and comparison with radiochromic film measurements / E. Ceccolini; I. Gerardy; J. Ródenas; M. Van Dycke; S. Gallardo; D. Mostacci. - In: RADIATION EFFECTS AND DEFECTS IN SOLIDS. - ISSN 1042-0150. - STAMPA. - 164:(2009), pp. 319-324. [10.1080/10420150902809270]

MCNP modelling of vaginal and uterine applicators used in intracavitary brachytherapy and comparison with radiochromic film measurements

MOSTACCI, DOMIZIANO
2009

Abstract

Brachytherapy is an advanced cancer treatment that is minimally invasive, minimising radiation exposure to the surrounding healthy tissues. Microselectron© Nucletron devices with 192Ir source can be used for gynaecological brachytherapy, in patients with vaginal or uterine cancer. Measurements of isodose curves have been performed in a PMMA phantom and compared with Monte Carlo calculation and TPS (Plato software of Nucletron BPS 14.2) evaluation. The isodose measurements have been performed with radiochromic films (Gafchromic EBT ©). The dose matrix has been obtained after digitalisation and use of a dose calibration curve obtained with a 6MV photon beam provided by a medical linear accelerator. A comparison between the calculated and the measured matrix has been performed. The calculated dose matrix is obtained with a simulation using the MCNP5 Monte Carlo code (F4MESH tally).
2009
MCNP modelling of vaginal and uterine applicators used in intracavitary brachytherapy and comparison with radiochromic film measurements / E. Ceccolini; I. Gerardy; J. Ródenas; M. Van Dycke; S. Gallardo; D. Mostacci. - In: RADIATION EFFECTS AND DEFECTS IN SOLIDS. - ISSN 1042-0150. - STAMPA. - 164:(2009), pp. 319-324. [10.1080/10420150902809270]
E. Ceccolini; I. Gerardy; J. Ródenas; M. Van Dycke; S. Gallardo; D. Mostacci
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/75462
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact