Medical linear accelerators are increasingly used in radiotherapy. During the operational life of the accelerator, the different components of the LINAC head become radioactive due to photonuclear reactions. Activation induced has to be evaluated to assess not only the dose due to residual activation but also the amount of radioactive waste that has to be managed in the dismantling phase of the facility. The aim of this work is to define a Monte Carlo approach for the preliminary assessment of activation levels of a LINAC head. In this work the MC code FLUKA was used to simulate the Elekta Precise Treatment System 15 MeV LINAC installed in 2004 at the Bellaria Hospital (Bologna, IT) and routinely used in radiotherapy treatments. The activation of the LINAC head was assessed in each component after 15 years of operation. The main long-lived radionuclides found in head components are W-181, Re-184, Ni-63, Co-57, Fe-55, Mn-54, while short-lived radionuclides are W-187, W-185, W-179, Re-188, Re-186, Re-184, Cu-64, Cu-62, Ni-65, Ni-57, Cr-55 and Mn-56. As expected the most active component is the target while no considerable activation were found in the ionization chamber and in the wedge.

Activation study of a 15MeV LINAC via Monte Carlo simulations / Vichi S.; Dean D.; Ricci S.; Zagni F.; Berardi P.; Mostacci D.. - In: RADIATION PHYSICS AND CHEMISTRY. - ISSN 0969-806X. - STAMPA. - 172:(2020), pp. 108758.1-108758.6. [10.1016/j.radphyschem.2020.108758]

Activation study of a 15MeV LINAC via Monte Carlo simulations

Vichi S.;Mostacci D.
2020

Abstract

Medical linear accelerators are increasingly used in radiotherapy. During the operational life of the accelerator, the different components of the LINAC head become radioactive due to photonuclear reactions. Activation induced has to be evaluated to assess not only the dose due to residual activation but also the amount of radioactive waste that has to be managed in the dismantling phase of the facility. The aim of this work is to define a Monte Carlo approach for the preliminary assessment of activation levels of a LINAC head. In this work the MC code FLUKA was used to simulate the Elekta Precise Treatment System 15 MeV LINAC installed in 2004 at the Bellaria Hospital (Bologna, IT) and routinely used in radiotherapy treatments. The activation of the LINAC head was assessed in each component after 15 years of operation. The main long-lived radionuclides found in head components are W-181, Re-184, Ni-63, Co-57, Fe-55, Mn-54, while short-lived radionuclides are W-187, W-185, W-179, Re-188, Re-186, Re-184, Cu-64, Cu-62, Ni-65, Ni-57, Cr-55 and Mn-56. As expected the most active component is the target while no considerable activation were found in the ionization chamber and in the wedge.
2020
Activation study of a 15MeV LINAC via Monte Carlo simulations / Vichi S.; Dean D.; Ricci S.; Zagni F.; Berardi P.; Mostacci D.. - In: RADIATION PHYSICS AND CHEMISTRY. - ISSN 0969-806X. - STAMPA. - 172:(2020), pp. 108758.1-108758.6. [10.1016/j.radphyschem.2020.108758]
Vichi S.; Dean D.; Ricci S.; Zagni F.; Berardi P.; Mostacci D.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/745929
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact