The objective of this study was to evaluate adverse events occurring during the lead period of custom-made fenestrated/branched endograft for juxtarenal/pararenal abdominal aortic aneurysm (j/p-AAA) and thoracoabdominal aortic aneurysm (TAAA).
The risk of aneurysm rupture and target visceral vessel occlusion during the lead period of custom-made fenestrated/branched endograft / Gallitto, Enrico; Faggioli, Gianluca; Spath, Paolo; Pini, Rodolfo; Mascoli, Chiara; Ancetti, Stefano; Stella, Andrea; Abualhin, Mohammhed; Gargiulo, Mauro. - In: JOURNAL OF VASCULAR SURGERY. - ISSN 0741-5214. - STAMPA. - 72 Issue1 Page16-24:1(2020), pp. 16-24. [10.1016/j.jvs.2019.08.273]
The risk of aneurysm rupture and target visceral vessel occlusion during the lead period of custom-made fenestrated/branched endograft
Gallitto, Enrico
;Faggioli, Gianluca
;Spath, Paolo
;Pini, Rodolfo
;Mascoli, Chiara
;Ancetti, Stefano
;Stella, Andrea
;Gargiulo, Mauro
2020
Abstract
The objective of this study was to evaluate adverse events occurring during the lead period of custom-made fenestrated/branched endograft for juxtarenal/pararenal abdominal aortic aneurysm (j/p-AAA) and thoracoabdominal aortic aneurysm (TAAA).I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.