Although in vitro biomechanical tests are regularly performed, the definition of a suitable reference frame for hemipelvic specimens is still a challenge. The aims of the present study were to: (i) define a reference frame for the human hemipelvis suitable for in vitro applications, based on robust anatomical landmarks; (ii) identify the alignment of a hemipelvis based on the alignment of a whole pelvis (including right/left and male/female differences); (iii) identify the relative alignment of the proposed in vitro reference frame with respect to a reference frame commonly used in gait analysis; (iv) create an in vitro alignment procedure easy, robust and inexpensive; (v) quantify the intra-operator repeatability and inter-operator reproducibility of the procedure. A procedure to univocally identify the anatomical landmarks was created, exploiting the in vitro accessibility of the specimen's surface. Through the analysis on 53 CT scans (106 hemipelvises), the alignment of the hemipelvis based on the alignment of a whole pelvis was analyzed: differences between male/female and right/left hemipelvises were not statistically significant To overcome the uncertainty in the identification of the acetabular rim, a standard acetabular plane was defined. An alignment procedure was developed to implement such anatomical reference frame. The intra-operator repeatability and the inter-operator reproducibility were quantified with four operators, on male and female hemipelvises. The intra-operator repeatability was better than 1.5°. The inter-operator reproducibility was better than 2.0°. Alignment in the transverse plane was the most repeatable. The presented procedure to align hemipelvic specimens is sufficiently robust, standardized, and accessible. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1645–1652, 2018.

Standardization of hemipelvis alignment for in vitro biomechanical testing / Morosato F.; Traina F.; Cristofolini L.. - In: JOURNAL OF ORTHOPAEDIC RESEARCH. - ISSN 0736-0266. - STAMPA. - 36:6(2018), pp. 1645-1652. [10.1002/jor.23825]

Standardization of hemipelvis alignment for in vitro biomechanical testing

Morosato F.
Primo
;
Traina F.
Secondo
;
Cristofolini L.
Ultimo
2018

Abstract

Although in vitro biomechanical tests are regularly performed, the definition of a suitable reference frame for hemipelvic specimens is still a challenge. The aims of the present study were to: (i) define a reference frame for the human hemipelvis suitable for in vitro applications, based on robust anatomical landmarks; (ii) identify the alignment of a hemipelvis based on the alignment of a whole pelvis (including right/left and male/female differences); (iii) identify the relative alignment of the proposed in vitro reference frame with respect to a reference frame commonly used in gait analysis; (iv) create an in vitro alignment procedure easy, robust and inexpensive; (v) quantify the intra-operator repeatability and inter-operator reproducibility of the procedure. A procedure to univocally identify the anatomical landmarks was created, exploiting the in vitro accessibility of the specimen's surface. Through the analysis on 53 CT scans (106 hemipelvises), the alignment of the hemipelvis based on the alignment of a whole pelvis was analyzed: differences between male/female and right/left hemipelvises were not statistically significant To overcome the uncertainty in the identification of the acetabular rim, a standard acetabular plane was defined. An alignment procedure was developed to implement such anatomical reference frame. The intra-operator repeatability and the inter-operator reproducibility were quantified with four operators, on male and female hemipelvises. The intra-operator repeatability was better than 1.5°. The inter-operator reproducibility was better than 2.0°. Alignment in the transverse plane was the most repeatable. The presented procedure to align hemipelvic specimens is sufficiently robust, standardized, and accessible. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1645–1652, 2018.
2018
Standardization of hemipelvis alignment for in vitro biomechanical testing / Morosato F.; Traina F.; Cristofolini L.. - In: JOURNAL OF ORTHOPAEDIC RESEARCH. - ISSN 0736-0266. - STAMPA. - 36:6(2018), pp. 1645-1652. [10.1002/jor.23825]
Morosato F.; Traina F.; Cristofolini L.
File in questo prodotto:
File Dimensione Formato  
POST-PRINT-MOROSATO-JOR-2018.pdf

Open Access dal 01/01/2020

Tipo: Postprint
Licenza: Licenza per accesso libero gratuito
Dimensione 1.28 MB
Formato Adobe PDF
1.28 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/722710
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 15
social impact