The aim of this work concerns the analysis and comparison of those modal parameters which are obtained by assessing two forced vibration tests, experienced on a laminated timber footbridge. The two tests were carried out five years apart to verify if the dynamic characteristics of the structure change considerably during its use. In particular, modal damping of the footbridge increases (that means an effective structural deterioration), whereas modal frequencies are substantially constant . It is noticeable that the analysis of the first test [1] highlighted that the natural frequencies of the structure were included in the range between 1 and 2 Hz, more similar to the frequency of the human step. This can entail possible amplifications of the oscillations of the structure during the passing of pedestrians (low comfort level for users). The analysis of the structural durability is necessary because the ordinary maintenance of the footbridge is not usually made, although the structure is subject to hard weather condition.

Forced vibration tests carried out on a laminated timber footbridge: comparisons five years apart / P. P. Diotallevi; O. Manfroni; C. Belmonte. - ELETTRONICO. - (2008). (Intervento presentato al convegno FOOTBRIDGE 2008 - Third International Conference tenutosi a Porto, Portugal nel 2-4 July 2008).

Forced vibration tests carried out on a laminated timber footbridge: comparisons five years apart

DIOTALLEVI, PIER PAOLO;MANFRONI, ODINE;BELMONTE, CLAUDIA
2008

Abstract

The aim of this work concerns the analysis and comparison of those modal parameters which are obtained by assessing two forced vibration tests, experienced on a laminated timber footbridge. The two tests were carried out five years apart to verify if the dynamic characteristics of the structure change considerably during its use. In particular, modal damping of the footbridge increases (that means an effective structural deterioration), whereas modal frequencies are substantially constant . It is noticeable that the analysis of the first test [1] highlighted that the natural frequencies of the structure were included in the range between 1 and 2 Hz, more similar to the frequency of the human step. This can entail possible amplifications of the oscillations of the structure during the passing of pedestrians (low comfort level for users). The analysis of the structural durability is necessary because the ordinary maintenance of the footbridge is not usually made, although the structure is subject to hard weather condition.
2008
Proceedings of the Conference FOOTBRIDGE 2008
Forced vibration tests carried out on a laminated timber footbridge: comparisons five years apart / P. P. Diotallevi; O. Manfroni; C. Belmonte. - ELETTRONICO. - (2008). (Intervento presentato al convegno FOOTBRIDGE 2008 - Third International Conference tenutosi a Porto, Portugal nel 2-4 July 2008).
P. P. Diotallevi; O. Manfroni; C. Belmonte
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/70871
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact